Kenmore 8907 Mobile home =additional installation requirements, Closet installation Dryer only

Page 7

II

Closet installation - Dryer only

(2.5cm) 174.7cm) d2.7cm)

AB

A.Side view - closet or confined area B. Closet door with vents

*Required spacing

**For side or bottom venting, 2" (5.1 cm) spacing is allowed.

Recessed or cJoset instaJJation = Dryer on pedestaJ

 

=

 

 

 

 

 

olo

 

 

14" m_.'

 

 

 

 

 

 

 

 

 

18I'.rain.*

 

\'-_J/

 

 

 

 

1,, -->I<--

1,,

 

 

 

(2.5cm)

(68.6cm)

(2.5 cm)

1"*

29.4"

5"_

 

 

 

12.5 cm)

(/4.7 cm)

(12.7 cm)

A

A. Recessed area

B. Side view - closet or confined area

*Required spacing

**For side or bottom venting, 2" (5.1 cm) spacing is allowed.

Installa_on spacing for cabinet installation

[] For cabinet installation, with a door, minimum ventilation openings in the top of the cabinet are required.

7" 117,8cm) 7'" (17.8 cm)

0""

(22.0 cm)

(12.7cm) _/4.7cm)

12.5cm)

12.5cm) (6&6cm) (2.5cm)

*Required spacing

**For side or bottom venting, 2" (5.1 cm) spacing is allowed.

Recommended instalia_on spacing for recessed or closet

instaJJation, with stacked washer and dryer

The dimensions shown are for the recommended spacing.

_-t _

, o>

 

24 in._ *

J_

._-- 1"'(2.5cn_)

 

 

(155 cm_)

 

 

*Required spacing

t

76"

(193 cm)

_-"

(2.5cm)

(2.5 cm)

 

 

(68.6cm)

*Required spacing

**For venting out the side, 2" (5.1 cm) spacing is allowed.

Mobile home =additional installation requirements

The installation of the Dryer in mobile homes must conform to the Manufactured Home Construction and Safety Standard Title 24 CFR, Part 32-80 {formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD (Part 280), 1975} for the United States) or CSA Standards Z240 (for Canada). When installing a Dryer in a mobile home, provisions for anchoring the Dryer to the floor must be made. Locate an area that has adequate fresh air.

A minimum of 72 in2 (183 cm 2)of unobstructed space is required.

All mobile home installations must be exhausted to the outside with the exhaust duct termination securely fastened to the

mobile home structure, using materials that will not support combustion.

The exhaust duct may not terminate underneath the mobile home.

See Exhausting section for more information.

IVlobile home installations require:

[] Metal exhaust system hardware, which is available for purchase from your local Sears store or Sears Service Center.

[] Special provisions must be made in mobile homes to introduce outside air into the dryer. The opening (such as a nearby window) should be at least twice as large as the dryer exhaust opening.

7

[BETTER]592-89075-02865

A-02 EN.indd

7

2011-03-23

i,_ft

9:49:12

I

 

 

 

Image 7
Contents Electric Dryer Table of Contents Protection Agreements Product Record Kenmore Appliance WarrantyPedestal Product Record Including Dryer SafetyYour safety and the safety of others are very important IMPORTANT Safety iNSTRUCTiONSMANUAL=BOOK PedestalHose Water You willneed Dryer DimensionsCustom undercounter installation Dryer only Explosion HazardIVlobile home installations require Mobile home =additional installation requirementsCloset installation Dryer only Installaon spacing for cabinet installationIt is your responsibility Electrical Shock HazardFlexible metal vent Fire HazardElbows ClampsDetermine vent path Special provisions for mobile home installationsOptional exhaust installations LOCATIONCONSiDERATiONSFlexible MetallicMETHOD1 Method2 Iii!!,Cilii!!!O¸¸S,OSwiii!i!!¸ iiiiii,!!!!iiiiilI BETTER592-89075-02865 02EN.indd 2011-03-23 94920 Models Dryer USEFire Hazard Models Air FluffDigital GraphicDisplay Dryness Level Salecon ButtonTemp Selection Button Wrinklerq Pr6venti0nduMixed Load Bell Suggested Items Suggested Temp Settings Installingthe drying rackHow to Set Setting/ReleasingLoad the dryer properly Cleanthe lintfilterDryer Care Explosion HazardPlastica shower curtains, outdoor furniture covers, etc Fromthe ExhaustVentTime WrinkleCycle Cooling Guard= Eeprom TroubleshootingLong, or lead istoo hot Loadsare wrinkled I94927 Iiiiiiiiiiiiiii =800=4= IiiiiiiiiiiiiiiilIiiiiiiiiiiiiiiiii Iiiiiiiiiiiiiii