Kenmore 110.6705, 110.6707, 110.6706 @ Sp el, If the dryer will not start, check the following

Page 17

3.Remove the 4 screws from the opposite side of the door.

I

,.-1

Install the 2 hinges to the front panel of the dryer using

4 screws. Use the non-slotted side to attach the hinge to the front panel.

Install screws in the top hinge holes in the door. Do not tighten screws. Leave approximately W' (5 mm) of screw exposed.

A. Install these screws first.

Hang door by placing screw heads into top slotted holes of hinges and slide door down. Align bottom screw holes in hinge and door. Install two bottom screws. Tighten all hinge screws.

7.Close door to engage door strike.

©@' Sp el_{!}

1.Check that all parts are now installed. If there is an extra part, go back through the steps to see which step was skipped.

2.Check that you have all of your tools.

3.Dispose of/recycle all packaging materials.

4.Check the dryer'sfinal location. Be sure the vent is not crushed or kinked.

5.Check that the dryer is level. See "Level Dryer."

6.For power supply cord installation, plug into an outlet. For direct wire installation, turn on power.

7.Remove any protective film or tape remaining on the dryer.

NOTE: Glass door models have a protective film on the window that should be removed.

8.Read "Dryer Use."

9.Wipe the dryer drum interior thoroughly with a damp cloth to remove any dust.

f0. Test dryer operation by selecting a Timed Dry heated cycle and starting the dryer. For this test, do not select the Air Only modifier.

If the dryer will not start, check the following:

Controls are set in a running or "On" position.

Start button has been pushed firmly.

Dryer is plugged into an outlet and/or electrical supply is on.

Household fuse is intact and tight, or circuit breaker has not tripped.

Dryer door is closed.

11.When the dryer has been running for 5 minutes, open the dryer door and feel for heat. If you feel heat, cancel cycle and close the door.

If you do not feel heat, turn off the dryer and check the following:

There may be 2 household fuses or circuit breakers for the dryer. Check that both fuses are intact and tight, or that both circuit breakers have not tripped. If there is still no heat, contact a qualified technician.

NOTE: You may notice an odor when the dryer is first heated. This odor is common when the heating element is first used. The odor will go away.

17

Image 17
Contents Oasis Protection Agreements Table of ContentsModel number Kenmore Eliteappliance WarrantyINSTRUCTiONS Dryer SafetyParts needed Parts suppliedDryer Dimensions Installation ClearancesMobile Home Additional Installation Requirements Mobile home installations requireIt is your responsibility If connecting by direct wireElectrical Connection If your outlet looks like thisStyle 1 Power supply cord strain relief Power Supply Cord Direct WireWire connection Power supply cord Style 2 Direct wire strain reliefWire connection Direct Wire CG F SJ J If this is a new vent system Vent material If using an existing vent systemRigid metal vent Flexible metal vent Special provisions for mobile home installations Optional exhaust installationsDetermine vent path Vent system chartRigid metal FlexibleReinstall the door If the dryer will not start, check the following @ Sp elTo make changes during an Auto Dry Cycle Dryer USEDrying tips To stop or pause your dryer at any timeHeavy Duty Cool DownNormal CasualAuto Dry Cycle Modifiers Auto Preset Cycle SettingsTimed Preset Cycle Settings Damp Dry Signal When using Air DryAir Dry Type of Load TimeChanging the Preset Dryness Level Settings As needed cleaning To cleanTo clean dryer drum Dryer CareFor direct-wired dryers Moving care For power supply cord-connected dryersFrom Inside the Dryer Cabinet From the Exhaust VentNo heat TroubleshootingUnusualsounds Dryer displaying code messageIs the exhaust vent the correct length? Are fabric softener sheets blocking the grille?Is the exhaust vent diameter the correct size? Explosion HazardContratos Maestros de Proteccibn ProteccionExclusion DE Garantias IMPLiCITAS Limitacion DE Recursos Garantja DE LOS Electrodomi Sticos Kenmore EliteSu seguridad y la seguridad de los demas es muy importante Seguridad DE LA SecadoraMY-HOME Usted necesitara Piezas suministradasPiezas necesarias 6cm Scm Usted es responsable deSi el contacto de pared luce come ste Si emplea un cable de suministro electricoSi el contacto de pared luce come este Si hace la conexibn con cableado directoCabledesuministroelctricoCabledirecto Conexibn de 4 hilos Cable de suministro elctrico Estilo 2 Protector de cables para cable directoCon Secci6n Conexibn de 4 hilos Cable directo CG F Conexibn de 3 hilos Cable directo Si usa un sistema de ventilacibn existente Peligro de Incendio Use un ducto de escape de metal pesadoInstalaciones recomendadas de escape Ducto de escape de metal flexible4cm Instalaciones opcionales de escape Determinacibn de la via del ducto de escapePeligro de Incendio SiguientePeligro de Peso Excesivo No. de Tipo deVueltas Ducto Ventilaci6n Angulares Vuelva a instalar la puerta C6mo invertir el topeSi la secadora no funciona, revise Io siguiente Para usar un ciclo de secado automtico USO DE LA SecadoraPara usar un ciclo programado Para hacer cambios durante un ciclo de secado automaticoPara hacer una pausa de la secadora en cualquier momento Para reanudar la marcha de la secadoraSugerencias de ciclos Luces indicadoras Indicator LightsHumedo Damp Enfriamiento Cool DownSecado expreso Express DRY TM Modiflcadores de los ciclos programados Seffal de semi seco Damp Dry SignalSecado al aire Air Dry Tipo de carga TiempoCbmo cambiar los ajustes prefijados de nivel de sequedad Sehal de ciclo Cycle SignalCambio de ciclos despu6s de presionar puesta en marcha Estante Para limpiar Cuidado DE LA SecadoraLimpieza segtn la necesidad Para lavarEn el ducto de escape En el interior del gabinete de la secadoraPara cambiar la luz del tambor Cuidado para las vacacionesLa secadora muestra mensajes codificados Sin calorManchas en la carga o en el tambor Serifs