Crosley CDE-8000GS, CDE-8000GW, CDE-8000GR, CDE-8000GBL manual Wire connection Direct wire

Page 16

4-wire connection : Direct wire

Important : Grounding through the neutral conductor is prohibited for (1) new branch-circuit installations, (2) mobile homes, (3) recreational vehicles, and (4) areas where local codes prohibit grounding through the neutral conductor. Prepare minimum 5 ft (1.52 m) of length in order for dryer to be replaced. First, peel 5 inches (12.7 cm) of covering material from end. Strip 5 inches of ground wire insulation. After cutting 11/2 inch (3.8 cm) from 3 other wires peel insulation back 1 inch (2.5 cm). Make ends of 3 wires a hook shape.

Then, put the hooked shape end of the wire under the screw of the terminal block (hooked end facing to the right) and pinch the hook together and screw tightly.

1.Connect neutral wire (white) of power cord to center terminal block screw.

2.Connect red and black wires to the left and right terminal block screws.

3.Connect ground wire (green) of power cord to external ground screw and move neutral ground wire of appliance and connect it to center screw.

4.Make sure that the strain relief screw is tightened.

Be sure that all terminal block nuts are on tight and power cord is in right position.

16

Image 16 Contents
Sensor Dry Your dryer provides sensor drying and time drying programsTime Dry Table of Contents SpecificationsWarranty Restriction Model Number Serial Number Date of PurchaseImportant Safety Instructions Read all instructions before using the applianceFor a grounded, cord-connected appliance For a permanently connected appliancePart 3 Initial Steps for Installing Your Dryer Positioning the DryerCloset Side View Closet DoorCloset-Front View Connecting the Exhaust System Clean old ducts before installing this dryerAlternate Exhaust Directions Remove screw and exhaust ductElectrical Plug Connections Procedure for Reversing the Door Preparation of the DryerConfirming Heat Source Operation Dryer AirflowPage Stacking Kit Installation InstructionsDRYER & Pedestal Part 4 Accessories InstallationUninstalling an electric dryer Instructions for Grounding of your Electric Dryer 120V/ 240V, 60 Hertz, 3-Wire InstallationImportant Warning Wire direct Wire connection Direct wire Wire connection Direct wire Option 1 4-wire connection with a power supply cord Option 2 3-Wire connection with a power supply cord Option 3 Optional 3-wire connectionPart 6 USER-MAINTENANCE Instructions Use Only for Short RunInstallationsExhaust Requirements and Instructions RecommendedExhaust and Dryer Maintenance Cleaning the Lint ScreenPart 7 Operating Your Dryer Select cycles designed for option Power Button Cycle SelectionStatus/Clean Filter/Wrinkle Care Indicator Time Change ButtonOption Buttons Estimated Time RemainingTime Dry Temp. ControlStarting your dryer Dry LevelBeeper Start / Pause ButtonPausing or restarting To use a manual dry cyclePart 8 Troubleshooting Guide Problem My Dryer Won’t StartProblem My Dryer Doesn’t Heat Problem There Are Greasy Spots On My ClothesProblem There Is Static In My Clothes After Drying Problem There Is Lint On My ClothesProblem The Drying Time Is Not Consistent Problem My Clothes Are Wrinkled Problem It Takes Too Long For My Clothes To DryProblem My clothes are shrinking Page About this Manual