Haier GDZ22-1 user manual English

Page 16

GDZ22-1 manual 10/22/01 11:45 AM Page 16

English

After installation is completed, the following method must be used to determine if the exhaust system is acceptable:

1.Connect an inclined or digital manometer between the dryer and the point the exhaust connects to the dryer.

2.Set the dryer timer and temperature to air fluff (cool down) and start the dryer.

3.Read the measurement on the manometer.

4.The system back pressure must not be higher than 0.75 inches of water column. If the system back pressure is less than 0.75 inches of water column, the system is acceptable. If the manometer reading is higher than 0.75 inches of water column, the system is too restrictive and the installation is unacceptable.

Although vertical orientation of the exhaust system is acceptable, certain extenuating circumstances could affect the performance of the dryer:

1.Only the rigid metal duct work should be used.

2.Venting vertically through a roof may expose the exhaust system to down drafts causing an increase in vent restriction.

3.Running the exhaust system through an area not insulated may cause condensation and faster accumulation of lint.

4.Compression or crimping of the exhaust system will cause an increase in vent restriction.

The exhaust system should be inspected and cleaned a minimum of every 18 months with normal usage. The more the dryer is used, the more often you should check the exhaust system and vent hood for proper operation.

15

Image 16
Contents Electric Dryer Sèche-Linge Électrique Secador-Eléctrico Important Safety Instructions Read all instructions before using the applianceFor Future Use Warranty service Table Of Contents Features Control KnobTemperature Knob Start KnobOther Features End of Cycle SignalLint Filter Leveling LegsOperations Normal Operating Sounds TipsCare and Cleaning Guide USE Your Dryer Without the Lint FilterTroubleShooting Dryer making noise when dryingDryer does not operate Dryer is working but not drying the clothesPower Supply Tools and Materials RequiredElectrical Requirements Unpacking Your DryerRequirements and Instructions Exhaust System ConnectionsExplosion hazard Materials English Installation in Recess or Closet Do Not Install Your DryerLocation of Your Dryer Installation in Mobile Home Electrical Connections For proper groundingWire Cord Connections Typical Conductor Cord English Limited Warranty Limited WarrantyDo Not Return This Product To The Store Haier America Trading, L.L.C New York, NY