American Dryer Corp D-78 SPECIFICATIONS/COMPONENT Identification, Specifications

Page 10

SECTION II

SPECIFICATIONS/COMPONENT IDENTIFICATION

A. SPECIFICATIONS

BASKET (TUMBLER) DIAMETER

 

44-1/2”

 

113 cm

BASKET (TUMBLER) DEPTH

 

24-7/8”

 

63.2 cm

BASKET (TUMBLER) MOTOR

 

1 HP*

 

0.746 kw

DOOR OPENING (DIAMETER)

 

31-3/8”

 

79.7 cm

BASKET (TUMBLER) VOLUME

 

22.4 cu. ft.

 

0.634 cu. m.

EXHAUST CONNECTION (DIAMETER)

 

10”

 

25.4 cm

DRYERS PER 20’/40’ CONTAINER

 

 

8/18

 

 

 

 

 

 

DRYERS PER 48’/53’ TRUCK

 

 

24/26

 

 

 

 

 

 

 

VOLTAGE AVAILABLE

 

120-460v

1ø-3ø 50/60 Hz

 

 

 

 

 

 

 

APPROX. WEIGHT (UNCRATED)

 

888 lbs

 

402.8 kg

 

 

 

 

 

 

Gas

APPROX. WEIGHT (CRATED)

 

938 lbs

 

425.5 kg

 

 

 

 

 

HEAT INPUT

 

204,000 btu/hr

51,408 kcal/hr

 

 

 

 

 

 

 

 

 

AIRFLOW 60 Hz

 

1,200 cfm

 

33.98 cmm

 

 

 

 

 

 

 

AIRFLOW 50 Hz

 

1,008 cfm

 

28.54 cmm

 

 

 

 

 

 

INLET PIPE CONNECTION**

 

3/4” F.P.T.

 

 

 

 

 

 

Shaded areas are stated in metric equivalents

 

 

 

*For non-reversing models only.

**A minimum of 3/4” pipe must be supplied to the gas inlet for each dryer.

NOTE: Manufacturer reserves the right to make changes in specifications at any time without notice or obligation.

6

Image 10
Contents Installation Manual Retain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Contents Reversing Timer SPIN/DWELL Adjustments Important Information Receiving and HandlingSafety Precautions What to do if YOU Smell GASPage SPECIFICATIONS/COMPONENT Identification SpecificationsSpecifications Component Identification Page Installation Procedures Location RequirementsUNPACKING/SETTING UP Dryer Enclosure Requirements Fresh AIR Supply Requirements Exhaust Requirements General Exhaust Ductwork InformationPage Page Page Electrical Information Electrical Requirements78 Gas Page SINGLE-PHASE 1Ø Electrical Connection Leads GroundPage Page GAS Information Type of GAS Page Page Preparation for OPERATION/START-UP Preoperational Tests Basket Tumbler Coating Preoperational Instructions Selection can be madeShutdown Instructions Service SERVICE/PARTS InformationParts Returning Warranty Cards Warranty InformationWarranty Cleaning Routine MaintenanceSuggested Cleaning Schedule Adjustments LubricationReversing Timer SPIN/DWELLADJUSTMENTS OPL Dual Timer Models onlyData Label Information Data LabelSerial Number F.E. System In Action OPL Sensoractivated Fire Extinguishing F.E. SystemInstallation Before YOU Start Check Local Codes and PermitsTypical water supply Optional Manual Bypass System Reset Sensor Activated Fire Extinguishing S.A.F.E System SensorActivated Fire Extinguishing S.A.F.E. System Coin Sensor Activated Fire Extinguishing F.E. System Installation Typical water supply Optional Manual Bypass Disabled Sensor Activated Fire Extinguishing S.A.F.E. System Sensor Activated Fire Extinguishing S.A.F.E System Qty ADC113373 04/01/02-25 12/12/02-25