IMPORTANT: No more than four (4) dryers (eight [8] baskets [tumblers]) can be connected to one

(1) common duct vent.

NOTE: The distance between the dryer single ducts being connected to the main common duct must be a minimum of 31-1/2” (80.01 cm) dryer’s width.

The ductwork should be laid out in such a manner where allowances are made at the rear area of the dryer for removal of rear service panels/guards.

IMPORTANT: Individual ducts being added to the main common vent must enter the main common vent ductwork at an angle not more than 45º in the direction of the airflow.

The illustration on the previous page shows the minimum cross-sectional area for multiple dryer venting.

The maximum length of venting from the last dryer to where it exhausts is the following:

VERTICAL - venting run must not exceed 8 feet (2.44 meters).

HORIZONTAL - venting run must not exceed 15 feet (4.6 meters).

These figures must be increased in proportion if the main duct run from the last dryer has numerous elbows or is unusually long. For extended runs or where more elbows are added, the cross-sectional area of the duct can only be increased to an extent and a professional heating, venting, and air conditioning (HVAC) firm should be consulted for proper venting information.

IMPORTANT: Exhaust back pressure must be no less than 0 and must not exceed 0.3 inches (0.74 mb) of water column (W.C.) when both baskets (tumblers) are operating.

NOTE: Inspection doors should be installed at strategic points in the exhaust ductwork for periodic inspection and cleaning.

22

Image 26
Contents ADG-530D II/WDA-530D Retain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Contents Section Procedure for Functional Check of Replacement Important Information Receiving and HandlingSafety Precautions What to do if YOU Smell GASPage Specifications SpecificationsSpecifications Installation Procedures UNPACKING/SETTING UPLocation Requirements Dryer Enclosure Requirements Fresh AIR Supply RequirementsPage Exhaust Requirements General Exhaust Ductwork InformationPage Page Page Page Page Page Page Page Page Page Important Venting Reminders Electrical Information Electrical RequirementsADG-530D Gas GAS Information Type of GAS Page Page Preparation for Operation Preoperational TestsPage Basket Tumbler Coating Operating Instructions Starting the DryerPage Shutdown Instructions Parts SERVICE/PARTS InformationService Warranty Warranty InformationReturning Warranty Cards Returning Warranty PartsPage Routine Maintenance CleaningAdjustments MonthsLubrication Troubleshooting SectionviiiFailed motor contactor/relay Microprocessor controller computer L.E.D. display reads dSFL Failed keyboard touch pad label assembly If dryer is equipped with optional battery backup Dryer operates, but is taking too long to dry Condensation on main door glass Datalabel LOCATION/INFORMATION Data LabelSerial Number Procedure for Functional Check Replacement Components