If you are using a power supply cord, a grounded electrical

outlet located within 2 ft (610 mm) of either side of the dryer.

See “Electrical Requirements.”

A sturdy floor to support the total dryer weight of 127 lbs

(57.6 kg). The combined weight of a companion appliance

should also be considered.

A level floor with a maximum slope of 1" (25 mm) under entire

dryer. (If slope is greater than 1" [25 mm], install Extended

Dryer Feet Kit, Part Number 279810.) Clothes may not tumble

properly and automatic sensor cycles may not operate

correctly if dryer is not level.

For a garage installation, you will need to place the dryer

at least 18" (460 mm) above the floor. If you are using a

pedestal, you will need 18" (460 mm) to the bottom of

Custom undercounter installation - Dryer only

 

 

2"*

 

 

(50 mm)

36" min

 

 

(914 mm)

 

 

1"*

27"

1"*

(25 mm)

(686 mm)

(25 mm)

*Required spacing

Closet installation - Dryer only

the dryer.

Do not operate your dryer at temperatures below 45ºF (7ºC). At lower temperatures, the dryer might not shut off at the end of an auto cycle. Drying times can be extended.

The dryer must not be installed or stored in an area where it will be exposed to water and/or weather.

Check code requirements. Some codes limit, or do not permit, installation of the dryer in garages, closets, mobile homes, or sleeping quarters. Contact your local building inspector.

Installation clearances

The location must be large enough to allow the dryer door to open fully.

Dryer Dimensions

 

14" max.*

48 in.2*

 

(356 mm)

 

 

 

(310 cm2)

 

18" min.*

 

 

(457 mm)

 

 

 

 

24 in.2*

 

 

 

(155 cm2)

1"*

28.65"

5"**

 

(25 mm) (728 mm)

(127 mm)

 

 

A

 

 

3"* (76 mm)

3"*

(76 mm)

B

50" (1283 mm)

36"

(914 mm)

*28.65"

 

(728 mm)

27"

(686 mm)

*Most installations require a minimum 5" (127 mm) clearance behind the dryer for the exhaust vent with elbow. See “Venting Requirements.”

Installation spacing for recessed area or closet installation

The following spacing dimensions are recommended for this dryer. This dryer has been tested for spacing of 0" (0 mm) clearance on the sides and rear. Recommended spacing should be considered for the following reasons:

Additional spacing should be considered for ease of installation and servicing.

Additional clearances might be required for wall, door, and floor moldings.

Additional spacing should be considered on all sides of the dryer to reduce noise transfer.

For closet installation, with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent ventilation openings are acceptable.

Companion appliance spacing should also be considered.

A. Side view - closet or confined area

B. Closet door with vents

*Required spacing

**For side or bottom venting, 0" (0 mm) spacing is allowed.

Recessed or closet installation - Dryer on pedestal

 

 

 

 

14" max.

 

 

 

 

(356 mm)

 

 

 

 

18" min.*

 

 

 

 

(457 mm)

1"

27"

1"

1"*

28.65"

5"**

(25 mm)

(686 mm)

(25 mm)

(25 mm)

(728 mm)

(127 mm)

AB

A. Recessed area

B. Side view - closet or confined area

*Required spacing

**For side or bottom venting, 0" (0 mm) spacing is allowed.

5

Image 5
Contents W10233410A Table of ContentsDryer Safety Table of ContentsPage Tools and Parts Installation InstructionsOptional Pedestal Location RequirementsDryer Dimensions Installation clearancesCustom undercounter installation Dryer only Closet installation Dryer onlyMobile home additional installation requirements Installation spacing for cabinet installationElectrical Requirements It is your responsibilityIf your outlet looks like this If connecting by direct wireStyle 1 Power supply cord strain relief Power Supply Cord Direct WireInstall strain relief Electrical ConnectionRemove center, silver-colored terminal block screw Wire connection Power supply cordStyle 2 Direct wire strain relief Wire connection Direct wire BDE CG F Optional 3-wire connection If this is a new vent system Vent material If using an existing vent systemVenting Requirements Do not use an exhaust hood with a magnetic latch Optional exhaust installationsPlan Vent System Alternate installations for close clearances Install Vent SystemVent system chart Special provisions for mobile home installationsRemove the door assembly Install Leveling LegsLevel Dryer Connect VentReverse the strike Rotate outer doorReverse hinge Reinstall the door Complete InstallationReattach door to dryer front panel with the 4 screws If the dryer will not start, check the followingTo use an Auto Cycle Press Stop once Adjust Dryness Level and/or OptionsDrying and Cycle Tips Stopping or Restarting Your DryerStatus Lights Lock ControlsCycles Options ModifiersChanging Cycles, Options, and Modifiers Drying Rack OptionsTo use the drying rack Rack Dry Setting Temp Time Wool SweatersStuffed toys or pillows Sneakers or canvas shoesCleaning the Lint Screen Cleaning the Dryer LocationCleaning the Dryer Interior Dryer CareVacation and Moving Care TroubleshootingChanging the Drum Light Dryer OperationCycle time too short Dryer ResultsDryer displaying code message Assistance or Service W10233410A Amana Laundry WarrantyThis limited warranty does not cover