Amana W10233410A Electrical Connection, Power Supply Cord Direct Wire, Install strain relief

Page 8

Electrical Connection

Power Supply Cord

 

Direct Wire

WARNING

Fire Hazard

Use a new UL listed 30 amp power supply cord.

Use a UL listed strain relief.

Disconnect power before making electrical connections.

Connect neutral wire (white or center wire) to center terminal (silver).

Ground wire (green or bare wire) must be connected to green ground connector.

Connect remaining 2 supply wires to remaining 2 terminals (gold).

Securely tighten all electrical connections.

Failure to do so can result in death, fire, or electrical shock.

WARNING

Fire Hazard

Use 10 gauge solid copper wire.

Use a UL listed strain relief.

Disconnect power before making electrical connections.

Connect neutral wire (white or center wire) to center terminal (silver).

Ground wire (green or bare wire) must be connected to green ground connector.

Connect remaining 2 supply wires to remaining 2 terminals (gold).

Securely tighten all electrical connections.

Failure to do so can result in death, fire, or electrical shock.

1.Disconnect power.

2.Remove the hold-down screw and terminal block cover.

C

D

B

A

A.Neutral ground wire

B.External ground conductor screw

C.Center, silver-colored terminal block screw

D.Terminal block cover and hold-down screw

Style 1: Power supply cord strain relief

Remove the screws from a ¾" (19 mm) UL listed strain relief (UL marking on strain relief). Put the tabs of the two clamp sections into the hole below the terminal block opening so that one tab is pointing up and the other is pointing down, and hold in place. Tighten strain relief screws enough to hold the two clamp sections together.

A

B

C

D

A. Strain relief tab pointing up

B. Hole below terminal block opening

C. Clamp section

D. Strain relief tab pointing down

3.Install strain relief.

8

Image 8
Contents Table of Contents W10233410ATable of Contents Dryer SafetyPage Installation Instructions Tools and PartsOptional Pedestal Location RequirementsInstallation clearances Dryer DimensionsCustom undercounter installation Dryer only Closet installation Dryer onlyInstallation spacing for cabinet installation Mobile home additional installation requirementsElectrical Requirements It is your responsibilityIf connecting by direct wire If your outlet looks like thisPower Supply Cord Direct Wire Style 1 Power supply cord strain reliefInstall strain relief Electrical ConnectionRemove center, silver-colored terminal block screw Wire connection Power supply cordStyle 2 Direct wire strain relief Wire connection Direct wire BDE CG F Optional 3-wire connection If this is a new vent system Vent material If using an existing vent systemVenting Requirements Do not use an exhaust hood with a magnetic latch Optional exhaust installationsPlan Vent System Install Vent System Alternate installations for close clearancesVent system chart Special provisions for mobile home installationsInstall Leveling Legs Remove the door assemblyLevel Dryer Connect VentReverse the strike Rotate outer doorReverse hinge Complete Installation Reinstall the doorReattach door to dryer front panel with the 4 screws If the dryer will not start, check the followingPress Stop once Adjust Dryness Level and/or Options To use an Auto CycleStopping or Restarting Your Dryer Drying and Cycle TipsStatus Lights Lock ControlsCycles Modifiers OptionsChanging Cycles, Options, and Modifiers Drying Rack OptionsRack Dry Setting Temp Time Wool Sweaters To use the drying rackStuffed toys or pillows Sneakers or canvas shoesCleaning the Dryer Location Cleaning the Lint ScreenCleaning the Dryer Interior Dryer CareTroubleshooting Vacation and Moving CareChanging the Drum Light Dryer OperationCycle time too short Dryer ResultsDryer displaying code message Assistance or Service W10233410A Amana Laundry WarrantyThis limited warranty does not cover