American Dryer Corp AD-20 installation manual Routine Maintenance, Suggested Cleaning Schedule

Page 34

SECTION VI

ROUTINE MAINTENANCE

A. CLEANING

A program and/or schedule should be established for periodic inspection, cleaning, and removal of lint from various areas of the dryer, as well as throughout the ductwork system. The frequency of cleaning can best be determined from experience at each location. Maximum operating efficiency is dependent upon proper air circulation. The accumulation of lint can restrict this airflow. If the guidelines in this section are met, an ADC dryer will provide many years of efficient, trouble free, and most importantly, safe operation.

WARNING: LINT FROM MOST FABRICS IS HIGHLY COMBUSTIBLE. THE

ACCUMULATION OF LINT CAN CREATE APOTENTIALFIRE HAZARD.

WARNING: KEEP DRYER AREA CLEAR AND FREE FROM COMBUSTIBLE

MATERIALS, GASOLINE, AND OTHER FLAMMABLE VAPORS AND LIQUIDS.

NOTE: Suggested time intervals shown are for average usage which is considered six (6) to eight (8) operational (running) hours per day.

IMPORTANT: Dryer produces combustible lint and must be exhausted to the outdoors. Every 6

months, inspect the exhaust ducting and remove any lint build up.

SUGGESTED CLEANING SCHEDULE

EVERY THIRD OR FOURTH LOAD

Clean the lint drawer every third or fourth load. A clogged lint drawer will cause poor dryer performance. The lint drawer is located on the lower front of the dryer. Inspect lint screen and replace if torn.

NOTE: The frequency of cleaning the lint drawer can best be determined from experience at each location.

WEEKLY

Clean lint accumulation from lint chamber, thermostat, and microprocessor temperature sensor (sensor bracket) area.

WARNING: TO AVOID THE HAZARD OF ELECTRICAL SHOCK, DISCONTINUE ELECTRICALSUPPLYTO THE DRYER.

30

Image 34
Contents AD-20 Installation Manual Retain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Contents Routine Maintenance Important Information Receiving and HandlingSafety Precautions Injury or Fire could ResultPage Specifications SpecificationsSpecifications AD-20 Installation Procedures UNPACKING/SETTING UPLocation Requirements Dryer Enclosure Requirements Fresh AIR Supply Requirements Exhaust Requirements Important Observe ALL governing codes and ordinancesImportant Venting Reminders Electrical Information Electrical RequirementsMust be Provided Page Page Page Electrical Service Specifications PER Dryer AD-20GAS Information Type of GAS Page Page Preparation for OPERATION/START-UP Preoperational Tests GAS Models onlyShut Down Instructions Service SERVICE/PARTS InformationParts Warranty Warranty InformationReturning Warranty Cards Returning Warranty PartsPage Cleaning Routine MaintenanceSuggested Cleaning Schedule Createapotential Fire Hazard Data Label Information Data LabelSerial Number ADC113379 10/16/02-25 10/17/02-250 12/03/02-250
Related manuals