38. Turn on cold water faucet

41. Move dryer to final location

Check that the water faucets are turned on.

39. Check for leaks

Check for leaks around “Y” connector, faucet, and hoses.

Connect vent

40. Connect vent to exhaust outlet

Move dryer to final location, taking care not to crush or kink vent.

After dryer is in place, remove corner posts and cardboard from under dryer.

Level dryer

42. Level Dryer

Place

level here

Using a 4" (102 mm) clamp, connect vent to exhaust outlet in dryer. If connecting to existing vent, make sure vent is clean. Dryer vent must fit over dryer exhaust outlet and inside exhaust hood. Check that vent is secured to exhaust hood with a 4" (102 mm) clamp.

Check levelness of dryer from side to side. Repeat from front to back.

NOTE: The dryer must be level for the moisture sensing system to operate correctly.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Not Level

 

LEVEL

 

 

Not Level

18

Image 18
Contents Electric Dryer Installation Instructions Dryer Safety Your safety and the safety of others are very importantInstallation Requirements Parts supplied all modelsParts supplied steam models Location Requirements You will needCloset installation dryer only Cabinet installation dryer onlyElectrical Requirements If connecting by direct wire Install Leveling LegsChoose a standard power supply cord connector Prepare dryer for leveling legsChoose electrical connection type Electrical ConnectionElectrical Connection Options Remove terminal block coverPrepare to connect neutral ground wire and neutral wire Wire Power supply cord ConnectionAttach power supply cord strain relief Attach power supply cord to strain reliefConnect neutral wire Connect ground wireConnect remaining wires Remove center screwAttach direct wire cable to strain relief Wire Direct Wire ConnectionAttach direct wire strain relief Prepare your 4-wire cable for direct connectionPrepare your 3-wire cable for direct connection Optional 3-wire Connection Connect external ground wireExhaust hoods Venting REQUiREMENTSRigid metal vent Elbows Special provisions for mobile homes Alternate exhaust installations for close clearance Plan Vent System Determine vent pathINStall Vent System Connect Inlet HoseTighten couplings Attach short hose and Y connectorAttach long hose to Y connector and tighten couplings Attach long hose to dryer fill valve and tighten couplingConnect vent Level dryerTroubleshooting Complete InstallationChecklist Tighten and adjust leveling legs2009 12/09 All rights reserved