9. Connect ground wire

F

A

Connect ground wire (F) (green or bare) of power supply cord to external ground conductor screw (A). Tighten screw.

10. Connect remaining wires

Connect remaining wires to outer terminal block screws. Tighten screws. Finally, reinsert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw. Now, go to Venting Requirements.

3-wire Power supply cord Connection

Use where local codes permit connecting cabinet-ground conductor to neutral wire.

B D E

A

CG F

A.3-wire receptacle (NEMA type 10-30R)

B.3-wire plug

C.Neutral prong

D.Spade terminals with upturned ends

E.3/4" (19 mm) UL listed strain relief

F.Ring terminals

G.Neutral (white or center wire)

11. Remove center screw

B

Remove center, silver-colored terminal block screw (B).

12. Connect neutral wire

C

B

 

Connect neutral wire (white or center wire) (C) of power supply cord to center, silver-colored terminal block screw (B). Tighten screw.

13. Connect remaining wires

Connect remaining wires to outer terminal block screws. Tighten screws. Finally, reinsert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw. Now, go to Venting Requirements.

10

Image 10
Contents Electric Dryer Installation Instructions Dryer Safety Your safety and the safety of others are very importantParts supplied all models Installation RequirementsParts supplied steam models Location Requirements You will needCloset installation dryer only Cabinet installation dryer onlyElectrical Requirements If connecting by direct wire Install Leveling Legs Choose a standard power supply cord connector Prepare dryer for leveling legsChoose electrical connection type Electrical ConnectionElectrical Connection Options Remove terminal block coverPrepare to connect neutral ground wire and neutral wire Wire Power supply cord ConnectionAttach power supply cord strain relief Attach power supply cord to strain reliefConnect neutral wire Connect ground wireConnect remaining wires Remove center screwAttach direct wire cable to strain relief Wire Direct Wire ConnectionAttach direct wire strain relief Prepare your 4-wire cable for direct connectionPrepare your 3-wire cable for direct connection Optional 3-wire Connection Connect external ground wireExhaust hoods Venting REQUiREMENTSRigid metal vent ElbowsSpecial provisions for mobile homes Alternate exhaust installations for close clearancePlan Vent System Determine vent pathINStall Vent System Connect Inlet HoseTighten couplings Attach short hose and Y connectorAttach long hose to Y connector and tighten couplings Attach long hose to dryer fill valve and tighten couplingConnect vent Level dryerTroubleshooting Complete InstallationChecklist Tighten and adjust leveling legs2009 12/09 All rights reserved