Maytag W10240583B-SP Wire Power supply cord Connection, Attach power supply cord strain relief

Page 9

Power supply cord strain relief:

5. Attach power supply cord strain relief

4-wire Power supply cord Connection

IMPORTANT: A 4-wire connection is required for mobile homes and where local codes do not permit the use of 3-wire connections.

A

B

F

 

 

A. Strain relief tab pointing up

B. Hole below terminal block opening C. Clamp section

D. Strain relief tab pointing down

A

B

C

D

C D EG

A.4-wire receptacle (NEMA type 14-30R)

B.4-prong plug

C.Ground prong

D.Neutral prong

E.Spade terminals with upturned ends

F.3/4" (19 mm) UL listed strain relief

G.Ring terminals

7.Prepare to connect neutral ground wire and neutral wire.

Remove screws from 3/4" (19 mm) UL listed strain relief (UL marking on strain relief). Put two clamp section tabs into hole below terminal block opening with one tab pointing up and one pointing down. Hold in place and tighten strain relief screws enough to hold two clamp sections together.

6. Attach power supply cord to strain relief

Put power supply cord through strain relief. Be sure that wire insulation on power cord is inside strain relief. Strain relief should be a tight fit with dryer cabinet and be in a horizontal position. Do not tighten strain relief screws at this point.

Now go to step 5 for 4-wire power supply cord connection or step 9 for 3-wire power supply cord connection.

E

B

A

Remove center, silver-colored terminal block screw (B). Remove neutral ground wire (E) from external ground conductor screw (A).

8. Connect neutral ground wire and neutral wire

C

B

E

Connect neutral ground wire (E) and neutral wire (white or center wire) (C) of power supply cord under center, silver- colored terminal block screw (B). Tighten screw.

9

Image 9
Contents Electric Dryer Installation Instructions Your safety and the safety of others are very important Dryer SafetyInstallation Requirements Parts supplied all modelsParts supplied steam models You will need Location RequirementsCabinet installation dryer only Closet installation dryer only Electrical Requirements Choose a standard power supply cord connector Install Leveling LegsIf connecting by direct wire Prepare dryer for leveling legsElectrical Connection Options Electrical ConnectionChoose electrical connection type Remove terminal block coverAttach power supply cord strain relief Wire Power supply cord ConnectionPrepare to connect neutral ground wire and neutral wire Attach power supply cord to strain reliefConnect remaining wires Connect ground wireConnect neutral wire Remove center screwAttach direct wire strain relief Wire Direct Wire ConnectionAttach direct wire cable to strain relief Prepare your 4-wire cable for direct connectionPrepare your 3-wire cable for direct connection Connect external ground wire Optional 3-wire ConnectionRigid metal vent Venting REQUiREMENTSExhaust hoods ElbowsPlan Vent System Alternate exhaust installations for close clearanceSpecial provisions for mobile homes Determine vent pathConnect Inlet Hose INStall Vent SystemAttach long hose to Y connector and tighten couplings Attach short hose and Y connectorTighten couplings Attach long hose to dryer fill valve and tighten couplingLevel dryer Connect ventChecklist Complete InstallationTroubleshooting Tighten and adjust leveling legs2009 12/09 All rights reserved