Maytag W10306460A-SP, W10096988A Optional 3-wire Connection, Connect external ground wire

Page 12

6. Connect neutral wire

B

C

Place hooked end of neutral wire (white or cente) (C) of direct wire cable under center terminal block screw (B). Squeeze hooked end together. Tighten screw.

7. Connect remaining wires

2. Connect neutral ground wire and neutral wire

B

E

C

Connect neutral ground wire (E) and neutral wire (white or center wire) (C) of power supply cord or cable under center, silver-colored terminal block screw (B). Tighten screw.

3. Connect remaining wires

Place hooked ends of remaining direct wire cable wires under outer terminal block screws (hooks facing right). Squeeze hooked ends together and tighten screws. Finally, reinsert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw. Now, go to

Venting Requirements.

Optional 3-wire Connection

You must verify with a qualified electrician that this grounding method is acceptable before connecting.

1. Prepare to connect neutral ground wire and neutral wire

E

B

A

Remove center, silver-colored terminal block screw (B). Remove neutral ground wire (E) from external ground conductor screw (A).

Place hooked ends of remaining wires under outer terminal block screws (hooks facing right). Tighten screws.

4. Connect external ground wire

A

G

Connect a separate copper ground wire (G) from the external ground conductor screw (A) to an adequate ground. Finally, reinsert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw. Now, go to

Venting Requirements.

12

Image 12
Contents Table of Contents Dryer Safety Tools and Parts Location RequirementsParts supplied Parts neededElectrical Requirements If connecting by direct wire Electrical ConnectionIf your outlet looks like this If your outlet looks like thisInstall Leveling Legs Prepare dryer for leveling legsScrew in leveling legs Electrical Connection Choose electrical connection typeRemove terminal block cover Electrical Connection OptionsPower Supply Cord Connection Wire Power Supply Cord ConnectionConnect ground wire Connect remaining wiresConnect neutral wire Remove center screwDirect Wire Connection Wire Direct Wire ConnectionPrepare your 3-wire cable for direct connection Venting RequirementsOptional 3-wire Connection Connect external ground wireVenting Requirements Rigid metal ventExhaust hoods ElbowsOptional exhaust installations Alternate installations for close clearancesPlan Vent System Venting KitsInstall Vent System Connect VentComplete Installation Checklist Level DryerLevel Dryer If the dryer will not start, check the followingReverse Door Swing Optional Troubleshooting Page W10096988A W10306460A-SP