Maytag W10096988A Connect ground wire, Connect remaining wires, Remove center screw

Page 9

5. Connect ground wire

A F

Connect ground wire (F) (green or bare) of power supply cord to external ground conductor screw (A). Tighten screw.

6. Connect remaining wires

Connect remaining wires to outer terminal block screws. Tighten screws. Finally, reinsert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw. Now, go to Venting Requirements.

3-wire Power Supply Cord Connection

Use where local codes permit connecting cabinet-ground conductor to neutral wire.

B D E

A

CG F

A.3-wire receptacle (NEMA type 10-30R)

B.3-wire plug

C.Neutral prong

D.Spade terminals with upturned ends

E.3/4" (19 mm) UL listed strain relief

F.Ring terminals

G.Neutral (white or center wire)

3.Remove center screw

B

Remove center, silver-colored terminal block screw (B).

4. Connect neutral wire

B

C

Connect neutral wire (white or center) (C) of power supply cord to center, silver-colored terminal block screw (B). Tighten screw.

5. Connect remaining wires

Connect remaining wires to outer terminal block screws. Tighten screws. Finally, reinsert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw. Now, go to Venting Requirements.

9

Image 9
Contents Table of Contents Dryer Safety Location Requirements Tools and PartsParts supplied Parts neededElectrical Requirements Electrical Connection If connecting by direct wireIf your outlet looks like this If your outlet looks like thisInstall Leveling Legs Prepare dryer for leveling legsScrew in leveling legs Choose electrical connection type Electrical ConnectionRemove terminal block cover Electrical Connection OptionsWire Power Supply Cord Connection Power Supply Cord ConnectionConnect remaining wires Connect ground wireConnect neutral wire Remove center screwWire Direct Wire Connection Direct Wire ConnectionVenting Requirements Prepare your 3-wire cable for direct connectionConnect external ground wire Optional 3-wire ConnectionRigid metal vent Venting RequirementsExhaust hoods ElbowsAlternate installations for close clearances Optional exhaust installationsPlan Vent System Venting KitsConnect Vent Install Vent SystemLevel Dryer Complete Installation ChecklistLevel Dryer If the dryer will not start, check the followingReverse Door Swing Optional Troubleshooting Page W10096988A W10306460A-SP