Power Supply Cord Connection

Power supply cord strain relief

1. Attach power supply cord strain relief

A

B

C

D

Remove the screws from a 3/4" (19 mm) UL listed strain relief (UL marking on strain relief). Put the tabs of the two clamp sections (C) into the hole below the terminal block opening

(B)so that one tab is pointing up (A) and the other is pointing down (D), and hold in place. Tighten strain relief screws just enough to hold the two clamp sections (C) together.

2.Attach power supply cord to strain relief

4-wire Power Supply Cord Connection

IMPORTANT: A 4-wire connection is required for mobile homes and where local codes do not permit the use of 3-wire connections.

A

B

 

F

 

 

 

 

C D

E

G

A.4-wire receptacle (NEMA type 14-30R)

B.4-prong plug

C.Ground prong

D.Neutral prong

E.Spade terminals with upturned ends

F.3/4" (19 mm) UL listed strain relief

G.Ring terminals

3.Prepare to connect neutral ground wire and neutral wire.

E

B

A

Put power supply cord through the strain relief. Be sure that the wire insulation on the power supply cord is inside the strain relief. The strain relief should have a tight fit with the dryer cabinet and be in a horizontal position. Do not further tighten strain relief screws at this point.

For 3-wire Power Supply Cord Connection, see page 8.

For 4 wire Power Supply Cord Connection, continue to step 3 on this page.

Remove center, silver-colored terminal block screw (B). Remove neutral ground wire (E) from external ground conductor screw (A).

4. Connect neutral ground wire and neutral wire

B

E

C

Connect neutral ground wire (E) and neutral wire (white or center) (C) of power supply cord under center, silver-colored terminal block screw (B). Tighten screw.

8

Image 8
Contents Table of Contents Dryer Safety Tools and Parts Location RequirementsParts supplied Parts neededElectrical Requirements If connecting by direct wire Electrical ConnectionIf your outlet looks like this If your outlet looks like thisScrew in leveling legs Install Leveling LegsPrepare dryer for leveling legs Electrical Connection Choose electrical connection typeRemove terminal block cover Electrical Connection OptionsPower Supply Cord Connection Wire Power Supply Cord ConnectionConnect ground wire Connect remaining wiresConnect neutral wire Remove center screwDirect Wire Connection Wire Direct Wire ConnectionPrepare your 3-wire cable for direct connection Venting RequirementsOptional 3-wire Connection Connect external ground wireVenting Requirements Rigid metal ventExhaust hoods ElbowsOptional exhaust installations Alternate installations for close clearancesPlan Vent System Venting KitsInstall Vent System Connect VentComplete Installation Checklist Level DryerLevel Dryer If the dryer will not start, check the followingReverse Door Swing Optional Troubleshooting Page W10096988A W10306460A-SP