Maytag W10306460A-SP, W10096988A Plan Vent System, Venting Kits, Optional exhaust installations

Page 14

Plan Vent System

Recommended exhaust installations

Typical installations vent the dryer from the rear of the dryer. Other installations are possible.

 

 

B

 

 

C

 

 

D

 

 

E

A

 

F

 

 

 

 

G

 

 

B

 

I

H

 

 

A.

Dryer

F.

Rigid metal or flexible metal vent

B.

Elbow

G.

Vent length necessary to connect elbows

C.

Wall

H.

Exhaust outlet

D.

Exhaust hood

I.

Optional side exhaust outlet

E.

Clamps

 

 

Optional exhaust installations:

Exhaust can be converted out the right side, left side, or through the bottom (4-way vent kit). Each kit includes step-by-step instructions. For ordering information, see “Venting Kits”.

ABC

A.Standard rear offset exhaust installation

B.Left or right side exhaust installation

C.Bottom exhaust installation

Alternate installations for close clearances

Venting systems come in many varieties. Select the type best for your installation. Two close-clearance installations are shown. Refer to the manufacturer’s instructions.

Over-The-Top installation (also available with one offset elbow)

Periscope installation

NOTE: The following kits for close clearance alternate installations are available for purchase.

Venting Kits

For more information, call 1-800-901-2042, or visit us at www.applianceaccessories.com. In Canada, call

1-800-807-6777 or visit us at www.whirlpoolparts.ca.

Part Number Descriptions

8171587RP 0–5" Metal vent periscope

4396037RP 0"-18" Metal vent periscope

4396011RP 18" - 29" Metal vent periscope

4396014 29" - 50" Metal vent periscope

4392892 In-Wall metal DuraVent™ Periscope

279818 4-way vent kit - white

W10186596 4-way vent kit - universal grey

4396028 Sure Connect™ venting kit (over-the-top installation)

4396009RP 5' Universal connect vent, flexible dryer venting

4396010RP 6' SecureConnect™ vent, flexible dryer venting

4396013RB Dryer vent installer’s kit

4396033RP 5' flexible dryer venting with clamps

4396727RP 8' flexible dryer venting with clamps

4396004 Dryer offset elbow

4396005 Wall offset elbow

4396006RW DuraSafe™ close elbow

4396007RW Through-the-wall vent cap

4396008RP 4" steel dryer venting clamps - 2 pack

8212662 Flush mounting louvered vent hood 4"

14

Image 14
Contents Table of Contents Dryer Safety Parts supplied Tools and PartsLocation Requirements Parts neededElectrical Requirements If your outlet looks like this If connecting by direct wireElectrical Connection If your outlet looks like thisScrew in leveling legs Install Leveling LegsPrepare dryer for leveling legs Remove terminal block cover Electrical ConnectionChoose electrical connection type Electrical Connection OptionsPower Supply Cord Connection Wire Power Supply Cord ConnectionConnect neutral wire Connect ground wireConnect remaining wires Remove center screwDirect Wire Connection Wire Direct Wire ConnectionPrepare your 3-wire cable for direct connection Venting RequirementsOptional 3-wire Connection Connect external ground wireExhaust hoods Venting RequirementsRigid metal vent ElbowsPlan Vent System Optional exhaust installationsAlternate installations for close clearances Venting KitsInstall Vent System Connect VentLevel Dryer Complete Installation ChecklistLevel Dryer If the dryer will not start, check the followingReverse Door Swing Optional Troubleshooting Page W10096988A W10306460A-SP