Graco 295616 important safety instructions Grounding the System

Page 10

Setup

5.Install air line (3/8 in. (76 mm) ID minimum) with quick disconnect air coupler (52) provided. See FIG. 8.

1.Pump: Connect Ground Wire (Y) to grounding screw (72) and tighten the screw securely. See FIG. 9. Connect the other end of the wire to a true earth ground. Make certain to comply with all National, State, and Local Electrical Codes.

Y

72

52

FIG. 8

Grounding the System

To reduce the risk of static sparking, ground the pump and all other equipment used or located in the pumping area. Check your local electrical code for detailed grounding instructions for your area and type of equipment. Ground all of this equipment.

WLD

FIG. 9

2.Air compressor: according to manufacturer’s recom- mendations.

3.Fluid hoses: use only grounded hoses with a maxi- mum of 300 ft (91 m) combined hose length to ensure grounding continuity. Refer to Hose Ground- ing Continuity.

4.Dispensing valve: grounding is obtained through connection to a properly grounded fluid hose and pump.

5.Object being sprayed: according to local code.

6.Fluid supply container: according to local code.

7.All solvent pails used when flushing, according to local code. Use only metal pails, which are conduc- tive. Do not place the pail on a non–conductive sur- face, such as paper or cardboard, which interrupts the grounding continuity.

8.To maintain grounding continuity when flushing or relieving pressure, always hold a metal part of the

spray gun/dispensing valve firmly to the side of a grounded metal pail, then trigger the gun/valve.

10

311882T

Image 10
Contents Important Safety Instructions Ratio Transfer PumpContents Equipment Misuse Hazard Foam Self-Ignition Moisture Sensitivity of IsocyanatesIsocyanate Hazard Keep Components a and B SeparateTypical Installation, without Circulation Key for FIGTypical Installation, with Circulation Typical Installation, with CirculationTypical Installation for Lubrication Applications Typical Installation for Lubrication ApplicationsAir Line Accessories InstallationSystem Accessories Fluid Line AccessoriesSetup Grounding the System Flushing Pressure Relief ProcedureOperation Daily StartupAir Motor Repair Series a Air ValveWLD Pump Lower Repair Remove pins 55. See FIG Seal stack enlarged to show detail Troubleshooting ReassemblyProblem Cause Solution Parts Model 51cPart Description Qty GASKET, PtfePart Description 103538 CLAMP, ground Part DescriptionFluid Drain Valve Qty Part DescriptionDimensions Technical DataT2 21 Ratio Transfer Pump Metric Performance Chart Key Air PressureGraco Standard Warranty Graco Information