Graco 295616 important safety instructions Equipment Misuse Hazard

Page 3

Warnings

WARNING

EQUIPMENT MISUSE HAZARD

Misuse can cause death or serious injury.

Do not operate the unit when fatigued or under the influence of drugs or alcohol.

Do not exceed the maximum working pressure or temperature rating of the lowest rated system component. See Technical Data in all equipment manuals.

Use fluids and solvents that are compatible with equipment wetted parts. See Technical Data in all equipment manuals. Read fluid and solvent manufacturer’s warnings. For complete information about your material, request MSDS forms from distributor or retailer.

Check equipment daily. Repair or replace worn or damaged parts immediately with genuine manu- facturer’s replacement parts only.

Do not alter or modify equipment.

Use equipment only for its intended purpose. Call your distributor for information.

Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.

Do not kink or over bend hoses or use hoses to pull equipment.

Keep children and animals away from work area.

Comply with all applicable safety regulations.

PRESSURIZED EQUIPMENT HAZARD

Fluid from the gun/dispense valve, leaks, or ruptured components can splash in the eyes or on skin and cause serious injury.

Follow Pressure Relief Procedure in this manual, when you stop spraying and before cleaning, checking, or servicing equipment.

Tighten all fluid connections before operating the equipment.

Check hoses, tubes, and couplings daily. Replace worn or damaged parts immediately.

MOVING PARTS HAZARD

Moving parts can pinch or amputate fingers and other body parts.

Keep clear of moving parts.

Do not operate equipment with protective guards or covers removed.

Pressurized equipment can start without warning. Before checking, moving, or servicing equipment, follow the Pressure Relief Procedure in this manual. Disconnect power or air supply.

311882T

3

Image 3
Contents Ratio Transfer Pump Important Safety InstructionsContents Equipment Misuse Hazard Keep Components a and B Separate Moisture Sensitivity of IsocyanatesIsocyanate Hazard Foam Self-IgnitionKey for FIG Typical Installation, without CirculationTypical Installation, with Circulation Typical Installation, with CirculationTypical Installation for Lubrication Applications Typical Installation for Lubrication ApplicationsFluid Line Accessories InstallationSystem Accessories Air Line AccessoriesSetup Grounding the System Daily Startup Pressure Relief ProcedureOperation FlushingSeries a Air Valve Air Motor RepairWLD Pump Lower Repair Remove pins 55. See FIG Seal stack enlarged to show detail Reassembly TroubleshootingProblem Cause Solution 51c Parts ModelGASKET, Ptfe Part Description QtyPart Description Part Description 103538 CLAMP, groundQty Part Description Fluid Drain ValveTechnical Data DimensionsT2 21 Ratio Transfer Pump Metric Key Air Pressure Performance ChartGraco Information Graco Standard Warranty