Graco 295616 important safety instructions Air Motor Repair, Series a Air Valve

Page 12

Air Motor Repair

Air Motor Repair

CAUTION

Air valve assembly has changed to series B for improved performance. Parts are not interchangeable between series A and B air motor. Series A air valves can be upgraded to series B with kit 262042.

1.Remove cap (1), cylinder (4), and square gaskets (3*). Inspect all parts, including spring under cap (not shown in FIG. 10) for damage and replace if necessary. See FIG. 10. Unscrew by hand or use a chain wrench to prevent distortion of the cylinder’s shape.

1

*3

4

*3

WLD

FIG. 10

NOTE: Cap (1) was replaced with a spring stop assem- bly for improved spring life. Existing pumps can be upgraded with Kit 24T043.

NOTE: Series A air motors have thin, flat, white seals in air valve. Series B (and later) air motors have thicker black seals in the air valve.

2.Series A air motors only: Loosen set screw (18) and unscrew air valve (5). If necessary to assist turning, wedge a screwdriver blade between the screw heads and the hex cap of air valve (5). Discard items 5, 13, 15, and 18. See FIG. 11.

*15

5

*13

18

FIG. 11: Series A Air Valve

3.Series B (and later Air Motors): Unscrew air valve (5). If necessary to assist turning, wedge a screwdriver blade between the screw heads and the hex cap of the air valve (5). Inspect o-rings (13* and 15*) for damage and replace if necessary. Ensure o-ring (13*) is correctly positioned and not pinched. See FIG. 12.

*15

5

*13

WLD

FIG. 12 Series B Air Valve

12

311882T

Image 12
Contents Important Safety Instructions Ratio Transfer PumpContents Equipment Misuse Hazard Moisture Sensitivity of Isocyanates Isocyanate HazardFoam Self-Ignition Keep Components a and B SeparateTypical Installation, without Circulation Key for FIGTypical Installation, with Circulation Typical Installation, with CirculationTypical Installation for Lubrication Applications Typical Installation for Lubrication ApplicationsInstallation System AccessoriesAir Line Accessories Fluid Line AccessoriesSetup Grounding the System Pressure Relief Procedure OperationFlushing Daily StartupAir Motor Repair Series a Air ValveWLD Pump Lower Repair Remove pins 55. See FIG Seal stack enlarged to show detail Reassembly TroubleshootingProblem Cause Solution Parts Model 51cPart Description Qty GASKET, PtfePart Description 103538 CLAMP, ground Part DescriptionFluid Drain Valve Qty Part DescriptionTechnical Data DimensionsT2 21 Ratio Transfer Pump Metric Performance Chart Key Air PressureGraco Standard Warranty Graco Information