Graco 295616 important safety instructions Pump Lower Repair

Page 14

Pump Lower Repair

Pump Lower Repair

1.Use a chain wrench near the top of the suction tube at the point indicated in FIG. 16, and a wrench on the flats of the foot valve (45) to loosen the foot valve from the suction tube (44). To prevent dam- age to the suction tube, do not remove the foot valve until instructed to do so in step 3.

Apply chain wrench approximately here

44

FIG. 16

NOTE: When removing the suction tube, be

very careful not to bend, dent, or damage it. To avoid damage, use the chain wrench only at the top and bottom of the suction tube as indicated in FIG. 16 and FIG. 17. Do not apply the wrench to the middle of the suction tube.

2.With the foot valve still in place to support the suc- tion tube, use a chain wrench near the bottom of the suction tube at the point indicated in FIG. 17, to loosen the suction tube (44) from the pump body (34).

3.Remove the foot valve assembly from the suction tube (44).

4.Remove retaining ring (46), snap ring (47), ball (71), and o-ring (38*) from foot valve (45). Inspect all parts for damage. See FIG. 17.

5.Remove suction tube (44) from pump body (34). See FIG. 18.

6.Inspect o-ring (38) on pump body and suction tube for damage. See FIG. 18.

38

 

Apply chain wrench

34

 

approximately here

 

44

44

46

47

71

*38

ti9976

FIG. 18

45

Apply chain wrench approximately here

ti9903

FIG. 17

14

311882T

Image 14
Contents Important Safety Instructions Ratio Transfer PumpContents Equipment Misuse Hazard Foam Self-Ignition Moisture Sensitivity of IsocyanatesIsocyanate Hazard Keep Components a and B SeparateTypical Installation, without Circulation Key for FIGTypical Installation, with Circulation Typical Installation, with CirculationTypical Installation for Lubrication Applications Typical Installation for Lubrication ApplicationsAir Line Accessories InstallationSystem Accessories Fluid Line AccessoriesSetup Grounding the System Flushing Pressure Relief Procedure Operation Daily StartupAir Motor Repair Series a Air ValveWLD Pump Lower Repair Remove pins 55. See FIG Seal stack enlarged to show detail Problem Cause Solution ReassemblyTroubleshooting Parts Model 51cPart Description Qty GASKET, PtfePart Description 103538 CLAMP, ground Part DescriptionFluid Drain Valve Qty Part DescriptionT2 21 Ratio Transfer Pump Metric Technical DataDimensions Performance Chart Key Air PressureGraco Standard Warranty Graco Information