Default 2D Sonar View

Customized 2D Sonar View

To Select Readouts:

1.Make sure you are in Advanced User Mode, highlight Select Readouts on the Setup main menu.

2.Use the RIGHT 4-WAY Cursor Control key to initiate this procedure.

3.The Select Readouts submenu will appear, showing a list of all Readouts. Use the UP or DOWN Cursor Control keys to select a particular Readout position, then use the RIGHT or LEFT Cursor Control keys to change what will be displayed at that position. (Off, Speed, Temperature, Triplog, Voltage, Water Speed)

Depth Offset

(Advanced)

Depth Offset will adjust the digital depth readout to indicate depth from the waterline or boat's keel. Enter a positive vertical measurement from the transducer to the waterline to read the depth from the waterline. Enter a negative vertical measurement from the transducer to keel to read the depth from the keel. This menu choice is available only when in Advanced User Mode (see Setup Menu Tab: User Mode.)

To change the Depth Offset setting:

1.Make sure you are in Advanced User Mode, then highlight Depth Offset on the Setup main menu.

2.Use the LEFT or RIGHT 4-WAY Cursor Control keys to change the Depth Offset setting. (-10.0 to +10.0 feet or -3 to 3 meters [International Models Only], Default = 0)

Temp Offset

(Advanced)

Temp Offset will adjust the temperature readout by the amount entered. This menu choice is available only when in Advanced User Mode (see Setup Menu Tab: User Mode.)

To change the Temp Offset setting:

1.Make sure you are in Advanced User Mode, then highlight Temp Offset on the Setup main menu.

2.Use the LEFT or RIGHT 4-WAY Cursor Control keys to change the Temp Offset setting. (-10.0 to +10.0 degrees, Default = 0)

Speed Calibration

(Advanced: with Temp/Speed Only)

Speed Calibration will adjust the speed readout by the percentage entered, and will appear in the menu if a Temp/Speed Accessory is connected and the paddlewheel has moved at least once, when the unit is in Advanced User Mode (see Setup Menu Tab: User Mode.)

To change the Speed Calibration setting:

1.Make sure you are in Advanced User Mode, then highlight Speed Calibration on the Setup main menu.

2.Use the LEFT or RIGHT 4-WAY Cursor Control keys to change the Speed Calibration setting. (-20% to +20%, Default = 0%)

49

50

Image 28
Contents Matrix 47 Operations Manual Table of Contents Thank YouAlarms Menu Tab Setup Menu TabViews Menu Tab Accessories Menu Tab Troubleshooting Sonar Menu Tab3D Sonar How Sonar Works2D Sonar Temperature water surface temperature What’s On the Display 3D ViewWhat’s On the Display 2D View Below the cursor3D Sonar View Views3D Sonar View 3D/2D Sonar Combo View Beam Sonar View3D/2D Sonar Combo View Beam Sonar ViewReal Time Sonar RTS Window 2D Sonar View2D Sonar View 2D Zoom View 2D Big Digits View2D Big Digits View 2D Zoom ViewBottom Presentation POWER/LIGHT Key Key FunctionsView Key Menu KeyAccessory Bus Powering Up the UnitMenu System Matrix 47 3D Title ScreenStart-Up Options Menu Normal OperationSelf Test Accessory Test SimulatorSystem Status PC Connect3D Bottom Zoom Sonar X-Press Menu3D Lower Range Reset View 3D History2D Sonar Window Beam SensitivityTo adjust the Upper Range To adjust the Lower RangeUpper Range Lower RangeBottom View Chart SpeedZoom Level Sonar Menu Tab 3D Bottom Style3D Frame Style Beam SelectFish Sensitivity Fish ID+Fish ID 3D Reference To change the RTS Window setting To change the Depth Lines settingDepth Lines Highlight RTS Window on the Sonar main menuSurface Clutter Noise FilterMax Depth Water TypeAlarms Menu Tab Depth AlarmFish ID Alarm To change the Depth Alarm settingLow Battery Alarm Alarm ToneSetup Menu Tab To change the Low Battery Alarm settingUser Mode Units DepthUnits Temp Units DistanceRestore Defaults Triplog ResetSelect Readouts Temp Offset Depth OffsetSpeed Calibration Nmea Output Views Menu TabFollowing Nmea sentences are output To turn Nmea Output on or offAccessories Menu Tab TroubleshootingNegative terminal or ground Fuse is operationalDisplay Problems Problem Possible CauseControl head loses power at high speeds Finding the Cause of NoiseMatrix Fishing System Accessories SpecificationsContact Humminbird