Humminbird 323 manual Bottom View, To adjust the Lower Range, To adjust the Chart Speed

Page 18

531444-1_A - 323_Man_English.qxd 11/5/2005 12:33 PM Page 34

Lower Range

Lower Range sets the deepest depth range that will be displayed. Automatic is the default setting. When in automatic mode, the lower range will be adjusted by the unit to follow the bottom. Selecting a specific setting locks the depth range into Manual mode. Use both Upper and Lower Range together to view a specific depth range manually when looking for fish or bottom structure.

Mwill be displayed in the lower right corner of the screen when you start manually adjusting the Lower Range to indicate that you are in Manual mode.

For example, if you are fishing in 60 feet of water but are only interested in the first 30 feet (surface to a depth of 30 feet) you should set the Lower Depth Range limit to 30. The display will show the 0 to 30 foot range, allowing you to see a more detailed view than you would see if the display went all the way to the bottom.

NOTE: A minimum distance of 10 feet will be maintained between the Upper and Lower Range regardless of the manual settings entered.

To adjust the Lower Range:

1.Highlight Lower Range on the Sonar X-PressTMMenu.

2.Use the LEFT or RIGHT 4-WAY Cursor Control keys to increase or decrease the Lower Range setting. (AUTO, 10 to 1000 feet, 3 to 330 meters [International Models Only], Default = AUTO)

Chart Speed

Chart Speed determines the speed at which the sonar information moves across the display, and consequently the amount of detail shown. A faster speed shows more information and is preferred by most anglers; however, the sonar information moves across the display quickly. A slower speed keeps the information on the display longer, but the bottom and fish details become compressed and may be difficult to interpret. Regardless of the Chart Speed setting, the RTS® Window will update at the maximum rate possible for the depth conditions. Adjust Chart Speed to your personal preference.

To adjust the Chart Speed:

1.Highlight Chart Speed on the Sonar X-PressTMMenu.

2.Use the LEFT or RIGHT 4-WAY Cursor Control keys to increase or decrease the Chart Speed setting. (1-9, Ultra, where 1 = Slow, 9 = Fast, Ultra = Fastest, Default = 5)

Bottom View

Bottom View selects the method used to represent bottom and structure on the display.

Inverse represents weak returns as dark pixels and strong returns as lighter pixels. This has the benefit of ensuring that weak signals will be clearly visible on the display.

Structure ID® represents weak returns as light pixels and strong returns as dark pixels. This has the benefit of ensuring that strong returns will be clearly visible on the display.

WhiteLine® highlights the strongest sonar returns in white resulting in a distinctive outline. This has the benefit of clearly defining the bottom on the display.

Bottom Black displays all pixels below the bottom contour as black, regardless of signal strength. This has the benefit of providing a high contrast between the bottom and other sonar returns on the display. Any targets such as fish, structure and thermoclines will be shown using the Structure ID® method.

See Bottom Presentation for more information.

27

28

Image 18
Contents Operations Manual Table of Contents Thank YouTroubleshooting Alarms Menu TabSetup Menu Tab Specifications Glossary Contact HumminbirdHow Sonar Works DualBeam Plus Sonar What’s On the Display Bait Ball Hard Bottom Rocky BottomSoft Bottom RTS Real Time Sonar Window Temperature water Do Not print this Views Sonar ViewUnderstanding Sonar History Real Time Sonar RTS WindowFreeze Frame Bottom Presentation Sonar Zoom View 200/83 kHz Split Sonar ViewKey Functions POWER/LIGHT KeyBig Digits View Circular Flasher ViewWAY Cursor Control Key Powering Up the UnitMenu Key Exit KeySonar Tab, Normal Mode Sonar Tab, Advanced Mode Menu SystemStart-Up Options Menu Normal OperationSimulator System Status Sonar X-PressTMMenu Accessory Test lists the accessories connected to SystemExit System Status by powering your Fishing System off Operation and the input voltageSensitivity To adjust the SensitivityTo adjust the Upper Range Upper RangeTo adjust the Chart Speed Chart SpeedTo adjust the Lower Range Lower RangeZoom Level Bottom LockBottom Range To use Beam Select Sonar Menu TabBeam Select Highlight Beam Select on the Sonar main menuFish ID+TM To change the Fish ID Sensitivity settingTo change the RTS Window setting Fish ID SensitivityZoom Width KHz SensitivityDepth Lines Surface Clutter Noise FilterMax Depth Alarms Menu Tab To change the Water Type settingWater Type Low Battery Alarm Depth AlarmFish ID Alarm Temp AlarmTo change the Alarm Tone setting Alarm ToneSetup Menu Tab Highlight Alarm Tone on the Alarms main menuUnits Temp User ModeUnits Depth Units DistanceTriplog Reset Restore DefaultsSelect Views Select Readouts Depth OffsetTemp Offset Troubleshooting To change the Speed Calibration settingSpeed Calibration Finding the Cause of Noise Display ProblemsProblem Possible Cause IsolationSpecifications GlossarySonar Terms 531444-1A 323ManEnglish.qxd 11/5/2005 1234 PM 531444-1A 323ManEnglish.qxd 11/5/2005 1234 PM Receiver See Transmitter 531444-1A 323ManEnglish.qxd 11/5/2005 1234 PM Contact Humminbird