3M 48N user manual Print, Reset, Run

Page 14

10

Operating:

Operating QUESTempº 48N

Print, reset, run

 

Print

 

Print

Allows printing to a parallel or serial printer or to a computer. The QUESTempº 48N will recognize the cable plugged in and configure itself for serial or parallel. If no cable is plugged in, it will default to serial. Press I/O Enter key to begin printing. Press Run/Stop key to return to the menu.

NOTE: if you wish to stop the printing, press I/O Enter key until you return to the main menu. When the printer has stopped printing, remove the cable from the printer to the instrument.

Reset

Resetting enables you to clear the logged data from memory. Press the I/O Enter key to enter the Reset mode. Clear the memory by holding down the I/O Enter key while the display counts down from three.

Run

For Data Logging setup, the run mode begins a session in memory and logs the data. For Event Logging, each run/stop is stored as an event and a numeric counter displays the number of saved events.

1.Begin a session by pressing the Run/Stop key from the view mode (or measurement view). An asterisk in the lower right corner indicates the run mode.

To toggle through the views, press the Up or Down Arrow.

Run indicator

Figure 1-14: Run mode indicator

2.End the session by pressing the Run/Stop key again. (The session will stop recording when the asterisk is no longer displayed.)

NOTE: If the logging memory is full or if there are no sensors plugged into the unit, attempting to enter the Run mode will result in an error message. If the memory capacity is exceeded, the asterisk in the lower right corner of the display will turn into an “F” and the memory remaining screen will show “0.0”.

Image 14
Contents Market Leader Contents List of Figures Iii Introduction QUESTempº 48N ModelPlacing the QUESTempº 48N on the job site Getting StartedUp and Running overview Keypad Operation Keys ExplanationTurning on, logging/capture an event, and turning off Index start-up screenIndicator arrow ∙ Numeric counterWaterless Wetbulb & Relative Humidity Sensor SensorsGlobe Thermometer Dry Bulb ThermometerWetBulb Globe Temperature Wbgt Stay Times/Rest Times IndiciesOperating QUESTempº 48N SetupSettings Explanation View Selecting Setup parameters 11 Selecting temperature setting and setupRun ResetPrint Following measurements can be accessed on the display Displayed Items19 Battery & memory screen Screen 6 Index Stay Time/IndexData Logging 22 Navy PHELs screenElectronic sensor check Performing an electronic sensor checkSensor Alignment RH Sensor AlignmentLow RH Alignment screen Adjust % to 33% using up/down arrow 27 RH alignment with Low % examplePrinting Data/CommunicationsParallel 30 Sample printoutsApproved 9-Volt Batteries PoweringVolt Alkaline Battery Replacement Duracell MN1604Appendix a Specifications MeasurementsWeight QUESTemp 48N Block Model LCDHeavy Very Heavy TLV Work and recovery LightAppendix B Heat Exposure Tables Heavy Very Heavy Action LimitPhel Curves Total Exposure Time in Hours Minutes Acgih Clothing CorrectionsUnited States Navy United States Navy Flag Degrees C Flag Conditions for U.S. Navy/Marine Corp. AshoreFlag Degrees F Appendix C Accessories sold separately QT3X-BCCommunicating and Downloading in DMS Appendix D SoftwareDMS quick overview PortData Finder and quick reports 34 Communicating with the QT⁰ 48N and DMSQuick Report select 36 Quick ReportCalibration Customer serviceWarranty Contacting 3M InstrumentationAbout Us