3M 48N user manual Appendix a Specifications, Measurements

Page 24

20

Appendix A

Appendix A: Specifications

Approved 9-Volt Batteries

Appendix A: Specifications

Measurements

Globe Temperature, Dry Bulb Temperature, Wet Bulb Temperature, % Relative Humidity, and WBGT Index

Temperatures given in Celsius or Fahrenheit

Index (displayed stay time with selected index): ACGIH TLV, U.S. Navy PHEL Charts, Flag Conditions for U.S. Navy/Marine Corp. Ashore

Data Logging mode and Event logging mode

Data logging mode records and prints all measurements at user selected interval of 1, 2, 5, 10, 15, 30, or 60 minutes.

Event logging mode (1 second record) 128K bytes of data memory.

Languages

English, French, Spanish, Italian, German

Sensors

Dry Bulb Sensor- 1000 Ohm Platinum RTD

Accuracy and Ranges: +/-0.5 from 0°C to 120°C (+/-0.9°F from 32°F to 248°F)

Waterless Wet Bulb (Humidity) Sensor

Accuracy and Ranges: Expanded measurement uncertainty of 1.1°C (k=2) between 0°C and 80°C (32°F and 176°F)

Globe Sensor- 1000 Ohm Platinum RTD

Accuracy and Ranges: +/-0.5 from 0°C to 120°C (+/-0.9°F from 32°F to 248°F)

Relative Humidity Sensor - Integrated circuit with capacitive polymer sensor

Accuracy and Ranges: +/-5% from 20 to 95% (non-condensing)

Operating Temperature Range

Sensor Assembly: -5°C to +100°C

Electronics: -5°C to 60°C

Housing

Designed water resistant to a light rain or mist. If rain is frequent, best practice would be to remote the sensor bar and keep the instrument sheltered.

Image 24
Contents Market Leader Contents List of Figures Iii Introduction QUESTempº 48N ModelGetting Started Up and Running overviewPlacing the QUESTempº 48N on the job site Keypad Operation Keys ExplanationTurning on, logging/capture an event, and turning off Index start-up screenIndicator arrow ∙ Numeric counterSensors Globe ThermometerWaterless Wetbulb & Relative Humidity Sensor Dry Bulb ThermometerWetBulb Globe Temperature Wbgt Stay Times/Rest Times IndiciesSetup Settings ExplanationOperating QUESTempº 48N View Selecting Setup parameters 11 Selecting temperature setting and setupReset PrintRun Following measurements can be accessed on the display Displayed Items19 Battery & memory screen Screen 6 Index Stay Time/IndexData Logging 22 Navy PHELs screenElectronic sensor check Performing an electronic sensor checkSensor Alignment RH Sensor AlignmentLow RH Alignment screen Adjust % to 33% using up/down arrow 27 RH alignment with Low % examplePrinting Data/CommunicationsParallel 30 Sample printoutsPowering Volt Alkaline Battery ReplacementApproved 9-Volt Batteries Duracell MN1604Appendix a Specifications MeasurementsWeight QUESTemp 48N Block Model LCDWork and recovery Light Appendix B Heat Exposure TablesHeavy Very Heavy TLV Heavy Very Heavy Action LimitAcgih Clothing Corrections United States NavyPhel Curves Total Exposure Time in Hours Minutes United States Navy Flag Conditions for U.S. Navy/Marine Corp. Ashore Flag Degrees FFlag Degrees C Appendix C Accessories sold separately QT3X-BCAppendix D Software DMS quick overviewCommunicating and Downloading in DMS PortData Finder and quick reports 34 Communicating with the QT⁰ 48N and DMSQuick Report select 36 Quick ReportCustomer service WarrantyCalibration Contacting 3M InstrumentationAbout Us