HEAT STRESS REPORT

 

File Name

_________________________ QUESTempº48N Rev 1.00

 

Serial # TK09090909

Employee

_________________________

 

Facility

_________________________ Session (3)

 

 

Start: 21-NOV-09

11:07:32

Department ________________________ Stop: 21-NOV-09 11:10:15

Job _________________________ Printed: 21-NOV-09 11:16:00

Comments/Notes______________________________________________

____________________________________________________________

Logging Interval: 1 minutes Degrees Fahrenheit

MAXIMUM LEVELS, Sensor 1

WBGT

68.3

21-NOV-09 11:10:08

DRY BULB

82.7

21-NOV-09 11:09:56

GLOBE

91.4

21-NOV-09 11:10:12

REL HUMIDITY

14%

21-FEB-08 11:07:32

FLOW (m/s)

0.6

21-FEB-08 11:09:08

MAXIMUM LEVELS, Sensor 2

WBGT

80.5

21-FEB-08 11:10:11

DRY BULB

99.2

21-FEB-08 11:09:07

GLOBE

106.1

21-FEB-08 11:10:06

HEAT INDEX

0

00-XXX-00 00:00:00

REL HUMIDITY

15%

21-FEB-08 11:07:32

MAXIMUM LEVELS, Sensor 3

WBGT

68.6

21-FEB-08 11:09:56

DRY BULB

88.6

21-FEB-08 11:10:08

GLOBE

93.0

21-FEB-08 11:10:03

HEAT INDEX

0

00-XXX-00 00:00:00

REL HUMIDITY

11%

21-FEB-08 11:07:32

MAXIMUM LEVELS, Sensor(WEIGHTED AVERAGE)

WBGT

71.4

21-FEB-08 11:10:14

EVENT: 1

 

 

 

 

 

Page 2

 

 

 

Sensor: 1

 

 

 

 

 

 

 

 

 

 

Degrees Fahrenheit

 

 

 

 

 

 

 

 

 

Stay Times: ACGIH, Acclimated, WBGT, clo correction = 1.0

°C

TIME WBGT

DRY GLOBE RH HI FLOW L

M

H

VH

 

11:08

67.9

82.4

90.7

13

0

0.5

60

60

60

60

 

11:09

68.1

82.6

91.3

12

0

0.5

60

60

60

60

 

EVENT: 2

 

 

 

 

 

Page 3

 

 

 

Sensor: 1

 

 

 

 

 

 

 

 

 

 

Degrees Fahrenheit

Stay Times: ACGIH, Acclimated, WBGT, clo correction = 1.0 °C

TIME WBGT

DRY GLOBE RH HI L

M

H

VH

11:08

79.3

98.9

104.5

15

0

60

45

30

15

11:09

80.2

99.2

105.6

15

0

60

45

30

15

EVENT: 3

 

 

 

 

 

 

Page 4

Sensor: 1

Degrees Fahrenheit

Stay Times: ACGIH, Acclimated, WBGTi, clo correction = 1.0 °C

TIME WBGT DRY GLOBE RH HI L

M

H

VH

11:08

68.1

88.0

92.7

11

0

60

60

60

60

11:09

68.4

88.3

92.9

11

0

60

60

60

60

EVENT: 4

 

 

 

 

 

 

Page 5

Sensor: WBGT(W-AVG) = .50*WBGT(1) + .25*WBGT(2) + .25*WBGT(3) Degrees Fahrenheit

Stay Times: ACGIH, Acclimated, WBGT, clo correction = 1.0 C WBGT WBGTo

TIME

W-AVG

W-AVG

L

M

H

VH

-----

-----

-----

---

---

---

---

11:08

71.5

70.8

60

60

60

60

11:09

71.8

71.1

60

60

60

45

Figure 1-30: Sample printouts

Image 22
Contents Market Leader Contents List of Figures Iii Introduction QUESTempº 48N ModelUp and Running overview Getting StartedPlacing the QUESTempº 48N on the job site Keypad Operation Keys ExplanationTurning on, logging/capture an event, and turning off Index start-up screenIndicator arrow ∙ Numeric counterWaterless Wetbulb & Relative Humidity Sensor SensorsGlobe Thermometer Dry Bulb ThermometerWetBulb Globe Temperature Wbgt Stay Times/Rest Times IndiciesOperating QUESTempº 48N SetupSettings Explanation View Selecting Setup parameters 11 Selecting temperature setting and setupPrint ResetRun Following measurements can be accessed on the display Displayed Items19 Battery & memory screen Screen 6 Index Stay Time/IndexData Logging 22 Navy PHELs screenElectronic sensor check Performing an electronic sensor checkSensor Alignment RH Sensor AlignmentLow RH Alignment screen Adjust % to 33% using up/down arrow 27 RH alignment with Low % examplePrinting Data/CommunicationsParallel 30 Sample printoutsApproved 9-Volt Batteries PoweringVolt Alkaline Battery Replacement Duracell MN1604Appendix a Specifications MeasurementsWeight QUESTemp 48N Block Model LCDHeavy Very Heavy TLV Work and recovery LightAppendix B Heat Exposure Tables Heavy Very Heavy Action LimitUnited States Navy Acgih Clothing CorrectionsPhel Curves Total Exposure Time in Hours Minutes United States Navy Flag Degrees F Flag Conditions for U.S. Navy/Marine Corp. AshoreFlag Degrees C Appendix C Accessories sold separately QT3X-BCCommunicating and Downloading in DMS Appendix D SoftwareDMS quick overview PortData Finder and quick reports 34 Communicating with the QT⁰ 48N and DMSQuick Report select 36 Quick ReportCalibration Customer serviceWarranty Contacting 3M InstrumentationAbout Us