ACGIH

Screening Criteria for Heat Stress Exposure. WBGT values in °C. NOTE: according to the ACGIH’s guidelines, the temperature values represent a work and rest process which is explained in the standards. Please refer to the ACGIH TLVs and BEIs for specific details.

 

Work and recovery

 

Light

Moderate

Heavy

Very Heavy

 

(TLV )

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

75% to 100%

 

31.0

28.0

26.0*

23.5*

 

 

 

 

 

 

 

 

50% to 75%

 

31.0

29.0

27.5

25.5*

 

 

 

 

 

 

 

 

25% to 50%

 

32.0

30.0

29.0

28.0

 

 

 

 

 

 

 

 

0% to 25%

 

32.5

31.5

30.5

30.0

 

 

 

 

 

 

 

 

Work and recovery

 

Light

Moderate

Heavy

Very Heavy

 

(Action Limit)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

75% to 100%

 

28.0

25.0

22.5*

20.0*

 

 

 

 

 

 

 

 

50% to 75%

 

28.5

26.0

24.0

22.5*

 

 

 

 

 

 

 

 

25% to 50%

 

29.5

27.0

25.5

24.5

 

 

 

 

 

 

 

 

0% to 25%

 

30.0

29.0

28.0

27.0

 

 

 

 

 

 

 

*Values not specified by ACGIH have been estimated for continuity.

Image 27
Contents Market Leader Contents List of Figures Iii QUESTempº 48N Model IntroductionGetting Started Up and Running overviewPlacing the QUESTempº 48N on the job site Keys Explanation Keypad OperationIndex start-up screen Turning on, logging/capture an event, and turning off∙ Numeric counter Indicator arrowDry Bulb Thermometer SensorsGlobe Thermometer Waterless Wetbulb & Relative Humidity SensorStay Times/Rest Times Indicies WetBulb Globe Temperature WbgtView SetupSettings Explanation Operating QUESTempº 48N11 Selecting temperature setting and setup  Selecting Setup parametersReset PrintRun Displayed Items Following measurements can be accessed on the displayStay Time/Index 19 Battery & memory screen Screen 6 Index22 Navy PHELs screen Data LoggingPerforming an electronic sensor check Electronic sensor checkRH Sensor Alignment Sensor Alignment27 RH alignment with Low % example Low RH Alignment screen Adjust % to 33% using up/down arrowData/Communications Printing30 Sample printouts ParallelDuracell MN1604 PoweringVolt Alkaline Battery Replacement Approved 9-Volt BatteriesMeasurements Appendix a SpecificationsWeight LCD QUESTemp 48N Block ModelHeavy Very Heavy Action Limit Work and recovery LightAppendix B Heat Exposure Tables Heavy Very Heavy TLVAcgih Clothing Corrections United States NavyPhel Curves Total Exposure Time in Hours Minutes United States Navy Flag Conditions for U.S. Navy/Marine Corp. Ashore Flag Degrees FFlag Degrees C QT3X-BC Appendix C Accessories sold separatelyPort Appendix D SoftwareDMS quick overview Communicating and Downloading in DMS34 Communicating with the QT⁰ 48N and DMS Data Finder and quick reports36 Quick Report Quick Report selectContacting 3M Instrumentation Customer serviceWarranty CalibrationAbout Us