Pelco CM9700MDD-EVS manual Power Connection, Units Powered, Wire Gauge Maximum Distance

Page 23

POWER CONNECTION

The CM9700MDD-EVS offers a single four-pin power connector. The RK5000PS-5U rack mount kit and the NET5301PS attach to the four-pin connector.

When using a different power supply, attach power to the enclosed four-pin to two-pin adapter and attach the adapter to the unit.

The CM9700MDD-EVS is designed to operate from either a 12 VDC or a 24 VAC power supply. It automatically senses power type and polarity (DC).

The CM9700MDD-EVS can be powered from many sources:

NET5301PS power supply connects directly to the four-pin connector on the CM9700MDD-EVS rear panel.

The RK5000PS-5U rack mount kit supplies power through the four-pin connector on the CM9700MDD-EVS rear panel as soon as the unit slides into place.

The Pelco MCS (B model), WCS (B model), and TF Series power supplies provide power through the four-pin to two-pin adapter (supplied), which then connects directly to the four-pin connector on the CM9700MDD-EVS rear panel.

Other UL Listed direct plug-in power units marked “Class 2” and rated for 12 VDC +10%/-15% or 24 VAC +10%/-15% provide power through the two-pin to four-pin adapter (supplied), which then connects directly to the four-pin connector on the CM9700MDD-EVS rear panel.

The power consumption of the CM9700MDD-EVS is 12 W (20 VA).

Use Table C to estimate your power requirements when installing multiple CM9700MDD-EVS units. This table is based on a 24 VAC power supply.

Table C. Powering Multiple Units

Units Powered

at 20 VA

at 48 VA

at 50 VA

at 100 VA

at 120 VA

at 240 VA

at 480 VA

 

 

 

 

 

 

 

1

2

2

4

5

11

24

 

 

 

 

 

 

 

Use Table D to help identify the necessary wire gauge and maximum cable distance. This table applies to two-conductor solid copper wire. (Reduce the distance by 10% for stranded copper wire.) These maximum distances are based on a maximum allowable voltage drop of 10%.

Table D. Recommended Wire Gauge and Maximum Wiring Distances

Wire Gauge

Maximum Distance

 

 

12 VDC

24 VAC

 

 

 

 

20 AWG (0.5 mm2)

59 ft (17 m)

237 ft (72 m)

18 AWG (1.0 mm2)

94 ft (28 m)

377 ft (114 m)

16 AWG (1.5 mm2)

149 ft (45 m)

599 ft (183 m)

14 AWG (2.5 mm2)

238 ft (72 m)

952 ft (290 m)

12 AWG (4.0 mm2)

377 ft (114 m)

1,511 ft (460 m)

10 AWG (6.0 mm2)

600 ft (182 m)

2,400 ft (731 m)

C1570M-C (5/06)

23

Image 23 Contents
CM9700MDD-EVS Matrix Digital Decoder Page Contents List of Illustrations List of Tables Regulatory Notices Regulatory NoticesCompatible Products Optional AccessoriesRecommended Power Supplies DescriptionRear View Front ViewImportant NOTE. Please Read Sample ApplicationBefore YOU Begin InstallationHardware Installation Overview Parts ListProduct Serial Number Label Product Serial Number Label PlacementMounting Desktop InstallationTighten the Thumbscrew to Secure the Unit Wall Mount InstallationTighten Thumbscrew to Secure the Unit Rack Mount InstallationPelco Badge Orientation Pelco Badge OrientationPin Label Lead Basic Hardware ConnectionsCM9700-CC1 Connection CM9700-CC1 Pin LeadCable Type Matrix BAY ConnectionCamera Monitor Camera Monitor CM9700MDD-EVS Camera Line Connector TipConnector Sleeve Common Audio Output ConnectionNetwork Connection NetworkWire Gauge Maximum Distance Power ConnectionUnits Powered Connecting the Power Network Video Recorder Configuration Software ConfigurationAdditional Optional Configuration Macro ConfigurationADD the CM9700MDD-EVS to the Matrix System Configuration Port Configuration Configuring CM9700MDD-EVS Settings Configure the CM9700MDD-EVS SettingsClick Next. The Device Identification page opens ADD Endura Cameras to the Matrix System ConfigurationClick Next, and then click Finish on the Add More Devices Configure a CM9700 Soft Alarm to Represent AN Endura Alarm WS5000 Add Script Dialog Box Macro ConfigurationC1570M-C 5/06 Sample NVR management scenario Network Video Recorder ManagementViewing NVRs in the Device Tree Configure a CM9700 Macro to Switch Video to a Backup NVR Associate a Soft Alarm with AN NVR Associate a Macro with a Soft AlarmExporting CM9700-MGR Configuration Files C1570M-C 5/06 Operation Front Panel IndicatorsDVR Menu Viewing VideoABC Viewing and Controlling Video 22 Ptz Function Keyboard Icon Menu Using Digital Zoom Recorded Video OnlyPause Recorded Video Current Mode = PauseFunction Play Recorded VideoPlayback Speed Current Mode = PlayPlay Recorded Video in Reverse Using the Alternate Cameras Feature Mode Function Unit Status Indicator Light CONFIGURATION/RESET ButtonProblem Possible Causes Suggested Remedy TroubleshootingModel SpecificationsRecommended Power Supplies Product Warranty and Return Information ISO9001