Figure 21. Number of Devices Page

Select the number of CM9700MDD-EVS units. Remember that one matrix bay input must be available for each CM9700MDD-EVS, so the number of units cannot exceed the number of available inputs on the matrix bay.

5.Click Next. The Port Configuration page opens, with the number of the first available port in the Host Port field. You can select a different port number; note however that it is strongly recommended that you use the default baud rate and parity settings, which are provided.

NOTE: All CM9700MDD-EVS units on a CM9700-CC1 node must have the same baud rate and parity settings. If you change these settings for a CM9700MDD-EVS unit, every unit on the node will be updated to match these settings when the CM9700-MGR configuration files are transferred to the CM9700MDD-EVS (as described in Export the Configuration Files and Transfer the Data to the CM9700MDD-EVS).

Figure 22. Port Configuration Page

6.Click Next, and then click Finish on the Add More Devices page. The specified number of CM9700MDD-EVS units is added to the node, as illustrated in Figure 23. Note that camera inputs 253-256 are assigned as the CM9700MDD-EVS tie lines.

Figure 23. Sample CM9700MDD-EVS Units Added to the Matrix System

7. Continue with the steps in the following section to configure additional CM9700MDD-EVS settings.

C1570M-C (5/06)

27

Image 27
Contents CM9700MDD-EVS Matrix Digital Decoder Page Contents List of Illustrations List of Tables Regulatory Notices Regulatory NoticesCompatible Products Optional AccessoriesRecommended Power Supplies DescriptionRear View Front ViewImportant NOTE. Please Read Sample ApplicationBefore YOU Begin InstallationHardware Installation Overview Parts ListProduct Serial Number Label Product Serial Number Label PlacementMounting Desktop InstallationTighten the Thumbscrew to Secure the Unit Wall Mount InstallationTighten Thumbscrew to Secure the Unit Rack Mount InstallationPelco Badge Orientation Pelco Badge OrientationPin Label Lead Basic Hardware ConnectionsCM9700-CC1 Connection CM9700-CC1 Pin LeadCable Type Matrix BAY ConnectionCamera Monitor Camera Monitor CM9700MDD-EVS Camera Line Connector TipConnector Sleeve Common Audio Output ConnectionNetwork Connection NetworkPower Connection Units PoweredWire Gauge Maximum Distance Connecting the Power Network Video Recorder Configuration Software ConfigurationAdditional Optional Configuration Macro ConfigurationADD the CM9700MDD-EVS to the Matrix System Configuration Port Configuration Configuring CM9700MDD-EVS Settings Configure the CM9700MDD-EVS SettingsClick Next. The Device Identification page opens ADD Endura Cameras to the Matrix System ConfigurationClick Next, and then click Finish on the Add More Devices Configure a CM9700 Soft Alarm to Represent AN Endura Alarm WS5000 Add Script Dialog Box Macro ConfigurationC1570M-C 5/06 Sample NVR management scenario Network Video Recorder ManagementViewing NVRs in the Device Tree Configure a CM9700 Macro to Switch Video to a Backup NVR Associate a Soft Alarm with AN NVR Associate a Macro with a Soft AlarmExporting CM9700-MGR Configuration Files C1570M-C 5/06 Operation Front Panel IndicatorsDVR Menu Viewing VideoABC Viewing and Controlling Video 22 Ptz Function Keyboard Icon Menu Using Digital Zoom Recorded Video OnlyPause Recorded Video Current Mode = PauseFunction Play Recorded VideoCurrent Mode = Play Play Recorded Video in ReversePlayback Speed Using the Alternate Cameras Feature Mode Function Unit Status Indicator Light CONFIGURATION/RESET ButtonProblem Possible Causes Suggested Remedy TroubleshootingModel SpecificationsRecommended Power Supplies Product Warranty and Return Information ISO9001