Specifications

Type

 

Description

 

 

 

Environmental Conditions

 

Operating Temperature

 

-30° to 70°C (-22° to 158°F)

 

 

 

Storage Temperature

 

-40° to 85°C (-40° to 185°F)

 

 

 

Humidity Range

 

<95% RH (non-condensing)

 

 

 

Altitude of Operation

 

3 km max.

 

 

 

Metering Category

 

US and Canada

 

CAT III; for distribution systems up to 347 V L-N /600 VAC L-L

 

 

 

CE

 

CAT III; for distribution systems up to 300 V L-N /480 VAC L-L

Dielectric Withstand

 

Per UL 508, EN61010

 

 

 

Conducted and Radiated

 

FCC part 15 Class B, EN55011/EN61000 Class B;

Emissions

 

(residential and light industrial)

Conducted and Radiated

 

EN61000 Class A (heavy industrial)

Immunity

 

 

 

 

 

Safety

 

US and Canada (cULus)

 

UL508 (open type device)/CSA 22.2 No. 14-05

 

 

 

Europe (CE)

 

EN61010-1:2001

 

 

 

* External DC current limiting is required, see fuse recommendations.

For use in a Pollution Degree 2 or better environment only. A Pollution Degree 2 environment must control conductive pollution and the possibility of condensation or high humidity. Consideration must be given to the enclosure, the correct use of ventilation, thermal properties of the equipment and the relationship with the environment.

Always use this product in the manner specified or the protection provided by the product may be impaired.

Provide a disconnect device to disconnect the meter from the supply source. Place this device in close proximity to the equipment and within easy reach of the operator, and mark it as the disconnecting device. The disconnecting device shall meet the relevant requirements of IEC 60947-1 and IEC 60947-3 and shall be suitable for the application. In the US and Canada, disconnecting fuse holders can be used. Provide overcurrent protection and disconecting device for supply conductors with approved current limiting devices suitable for protecting the wiring. If the equipment is used in a manner not specified by the manufacturer, the protection provided by the device may be impaired.

FCC PART 15 INFORMATION

NOTE: This equipment has been tested by the manufacturer and found to comply with the limits for a class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a residential environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area may cause harmful interference in which case the user will be required to correct the interference at his own expense. Modifications to this product without the express authorization of the manufacturer nullify this statement.

N998

© 2011 Schneider Electric All Rights Reserved.

3

Image 7
Contents EM3555 Please Note Hazard Categories Special SymbolsFCC Notice Contents EM3555 ZL0093-0A Contents 11/2011 Screw Mounting Safety PrecautionsInstallation Overview DIN Rail MountingType Description SpecificationsEnvironmental Conditions SafetyMetering Category Introduction Observe correct CT orientation when installing the deviceParts of the EM Series EM Series Dimensions DimensionsData Output Full Data Set FDS Data OutputData Logging Attach mounting clips for DIN Rail InstallationSupported system types Single-Phase WiringThree-Phase Wiring Supported System TypesSymbol Description WiringWiring Symbols Use System Type 11 2L Wiring DiagramsDiagram Diagram Phase 4-Wire Wye Connection 3 CT 3 PTL1 L2 L3 Control PowerWiring Notes Fuse RecommendationsDisplay Screen Display Screen DiagramQuick Setup Instructions Solid State Pulse Outputs SOLID-STATE Pulse OutputDescription UI Menu Abbreviations DefinedMain Menu IEC and Ieee AbbreviationsFor Data Configuration EM3555 User Interface for Data Configuration Ploss Lowpf ERR OVR Pulse ALERT/RESET InformationFrom User Interface for SetupEM3555 ZL0093-0A User Interface for Setup 11/2011 RS-485 Communications Daisy-chaining Devices to the Power MeterRead/Write Collision ConfigurationData Logging Reading DataSetting Value Modbus Register Standard Modbus Default SettingsModbus Default Settings Modbus Point MAP Supported Modbus CommandsCommand Description Supported CommandsSunSpec Alliance Interoperability Specification Compliance Format Units Scale Range Description Integer Data Summary of Active PhasesFormat Units Scale Range 055 ULong KVARh Accumulated Q1 Reactive 079 ULong KVAh Accumulated Apparent Register 142 NV UInt 143 10000 144 500 250 145 Msec 146 LSB Logging Configuration and Status161 UInt 32767 162 163 164 0xFFFF ULong KWh 165 166 Month Floating Point Data Summary of Active Phases Floating Point Data Per Phase Logging Interface SunSpec 1.0 Common Model Sunspec Compliant Common and Meter Model Register BlocksRegister Format Units Scale Range SunSpec Description NameName SunSpec DescriptionSunSpecCompliantCommonandMeterModelRegisterBlocks Event Bit Description China Rohs Compliance Information Efup Table TroubleshootingProblem Cause Solution TroubleshootingEM3555 Installation Guide Schneider Electric

EM3555 specifications

Schneider Electric EM3555 is a highly efficient energy monitoring device that plays a crucial role in optimizing energy management across various applications. As part of Schneider Electric’s extensive range of products, the EM3555 is designed for professionals who seek robust solutions for monitoring energy usage and improving operational efficiency.

One of the main features of the EM3555 is its advanced energy consumption monitoring capabilities. It provides real-time data on electrical parameters, including voltage, current, frequency, power factor, and active/reactive power. This level of detailed information helps organizations understand their energy consumption patterns, identify inefficiencies, and take corrective actions to enhance energy performance.

The EM3555 is equipped with a user-friendly display that allows for easy access and navigation through various metrics. This display offers visibility into key performance indicators and alerts users to any anomalies in energy consumption. Enhanced energy visibility is critical for effective decision-making and is particularly beneficial in environments where energy management is paramount.

In terms of technology, the EM3555 incorporates the latest communication protocols, including Modbus RTU. This feature facilitates seamless integration with existing systems, enabling users to collect and analyze data efficiently. Furthermore, the EM3555 can be connected to Schneider's EcoStruxure platform, which offers advanced analytics and insights into energy usage, harnessing the power of IoT for smarter energy management.

Another notable characteristic of the EM3555 is its compact design, making it suitable for various installation environments, including electrical panels and equipment rooms. The device is built to withstand harsh industrial conditions, ensuring long-term reliability and durability.

In conclusion, the Schneider Electric EM3555 is an exemplary energy monitoring solution that combines advanced features, cutting-edge technology, and robust characteristics. By providing real-time insights into energy consumption, the EM3555 empowers organizations to improve their energy efficiency, reduce costs, and contribute to sustainability goals. Its integration capabilities with other systems further underline its value in contemporary energy management practices. With the EM3555, Schneider Electric continues to lead the way in developing innovative solutions for a more sustainable future.