remote screen information
Advanced Alternator Regulator |
| |
Display and | on/off | |
Diagnostics Panel |
| |
Default | Bat 14.4v Timer |
|
volts | alarm | |
Screen | Alt 15.4v 134m | light |
|
| |
Help | System |
|
set up |
| |
System Trip |
| |
|
| |
| System Disengaged |
|
temp | Low voltage warning |
|
| System Within Limits |
|
| Sterling power products | CE |
B
A
THERE ARE 3 DIFFERENT WAYS TO MOUNT THE REMOTE SLIDE PARTS A TO EXPOSE SCREW HOLES
1)FOR FLUSH MOUNT, REMOVE PART B
2)FOR SURFACE MOUNT KEEP PART B
3)FIT THROUGH A METAL PANEL
AFTER INSTALLATION REPLACE PARTS A
BAT 14.1V BULK ALT 14.4V CALC.
BULK CHARGE
WET OPEN
SYSTEM SET: 12V xxx min. ACTIVE
BAT TEMP: 20C
ALT TEMP: 60C
Push the volts button.
this gives the battery voltage and the alternator voltage, this would be the main screen
Push the arrow button.
this give the charger stage , it bulk charger ( high charger rate ) or float charger ( job done ), the bulk charger will change to a count down timer ( ie how long before the bulk charger is over and t will beguine ) l it also gives you the type of battery the system is set up for, ie wet, gel, A.G.M. etc.
Push button setup.
This gives the system set up information, ie it is set for 12 volt operation or 24 v , anh the time the system has been active ( engine running time from start up )
Push button temp.
This gives the battery and alterbnator temperature ( if the sensors are