Sterling Power Products PDARRC manual Fault on panel Red high battery voltage trip light on

Page 15

done after the alarm has gone off are pointless ) , the voltage at the domestic battery and the voltage at the engine battery . if you get results on a split diode system like, alt volts 16 volts, eng batt 15 volts , domestic battery 12 volts, then the domestic battery is not connected to the alternator, the most likley cause of this is failure of the split charger diode, or failure of the split charger relay. check the relay or diode .

For a split charger relay, go to the 2 x main connectors on the relay, and ensure that the voltage into the relay is the same as the voltage coming out, if there is a difference of more that 0.2 volts then the relay is not working. Solution replace the relay .

With a split charger diode, check the input voltage of the diode and the out put voltage to the domestic battery, there should be a voltage drop of between 0.6 and 1.2 volts, if however there is more than this the diode has failed, Solution :replace the diode.

Fault on panel: Red high battery voltage trip light on

This trip has been activated because the battery voltage ( at the end of the red sense wire ) has exceeded 15.5 volts ( x 2 for 24 volts ). the max charge voltage from the advanced reg is 14.8 volts, therefore it is not possible for this trip to be activated under normal circumstances.

There are only 3 possibilities for this trip to come on :

1)the sterling advanced regulator has failed closed and has started to over charger the batteries

2)the standard alternator regulator has failed closed and gone to over charger the batteries

3)the red sense wire has been disconnected

How to determine which, and what to do about it

Put a volt meter on the domestic battery, ( or where ever the red sterling sense wire goes to ), start the engin up, watch the battery voltage climb up and up, once it gets to 15.5 volts and the unit trips, if the voltage continues to climb then the standard alternator regulator has failed and there is nothing we can do about this except warn you. This is the worst and most dangerous fault you can get on a alternator system, and the alternator must be fixed as soon as possible, if a long journey must be undertaken then remove the b+ ( positive cable ) from the back of the alternator, and get to port and repair the problem . Failure to fix this problem will result in the total loss of the batteries and other equipment on the boat and a possible fire as well.

If however after the voltage reaches 15.5 volts and the advanced reg warning light comes on and the voltage drops away down to 13-14 volts, then the sterling advanced regulator is 100% at fault and must be replaced or repaired. For emergency use only it is o.k. to motor to port with this condition as the Sterling regulator has automatically switched itself off

Fault on panel: Red High battery voltage light flashing

High battery temp trip

This has been activated because the thermal sensor provided with the advanced regulator has picked up a temperature in excess of 50 degc. There are a few very obviouse reasons fr this and a few subtle. The important thing to find out is where the temperature sensor is, and to expose where it is.

1)the most obvious fault is the fact that the batteries are actually very hot, ie 50 def c is just about to hot to touch, if this is the case the batteries will be on there way to boiling and are certainly in a major failure event . if this is the case then switch off the engine and find out why.

If all the batteries are presenting the same heat then you are overcharging the batteries, or are simply in a very hot environment where the batteries should not be. If however only 1 battery is hot and the rest are cooler then it is simply a scrap battery, take it out of circuit and replace it.

2)the temperature sensor should be connected to the lead post at the top of a battery, in the event of the terminals becoming lose, or a high current is being passed then it is possible for the battery terminal to over heat and set of the alarm, when in fact the batteries are o.k. . this should be very obvious, feel the temp of the post where the thermal sensor is, and feel the batteries, if the post is hot and the battery is cold the fix the bad connections in your battery terminal.

Image 15
Contents Sterling Power Products Fan POS+ Control box Alternator temperature sensorAlternator type Selector insideRemote screen information Amps For Alternator Type Will say again for people who thing I am jokingSet Up Advanced Regulator Before Installation Extend a little as possible Want Testing the systemBattery Maintenance See for the relevent l.e.d Where to fit Alternator Temperature sensor see part a+ disengage see part d Battery Temperature sensor see part cHelpful hints to find the Faults Indicated by the l.e.d.s Fault on panel Red high battery voltage trip light on Volts neg Carbon brushes Copper slip rings On rotor Alternator Stator VoltsNeg Volts Volts NegVolts Neg B Explanation for Positive field control alternators M CH1 134 a 345 A/Hr Batterie-Typ Volt oder 24 VoltLichtmaschinen-Spannung und Leistung Lichtmaschinen-TypEinbau Die Identifizierung des Feld-Kontroll-Kabels DF AnschlussGEL & AGM Batterien amerikanische Spezifikation Volt Kabel 2 = Schalter Batterietyp SchalterSpannungAnschluss des Batterie-Temperatur-Sensors Anschluss des Lichtmaschinen-Temperatur-SensorsSchalter Sicherung Einbauhinweise und Erklärungen Ausgeschaltet Schwarz 2 x Absicherung mit je 5A SicherungenWEISSAbsicherung mit 5A Sicherung Gelb Absicherung mit 2A Sicherung ROT Absicherung mit 2A SicherungSchaltrelais WechselschalterWichtiger Hinweis FunktionstestWartung der Batterien Fragen UND AntwortenPage LED LED 9 LED POS+ Als Aufbaugerät Ort der InbetriebnahmeLieferumfang Benötigte Werkzeuge und TeileAnzeige der Spannung Anschluss des GerätesFunktionen im Monitor Modus Motor ist abgeschaltet Als Hinterbaugerät im SchaltpanelBetrieb des Hochleistungsreglers Funktionen im Betriebsmodus Motor läuftUnterspannungsschutz Ein- und Ausschalten des HochleistungsreglersSetup Anzeige FehlermeldungenTemperaturanzeige Taste light Taste alarm