AOUT=

DVST Installation GuideAlarms & Events

AOUT=

Set alarm outputs AUTO / MANUAL

 

(default is AUTO)

 

The two alarm contacts can be configured for automatic or manual

 

operation.

 

AUTO

 

In automatic mode relay 1 acts as a line indicator and closes whenever

 

the DVST is on line.

 

MANUAL

 

In manual mode the AUX1 key on the local unit controls relay 1 on the

 

remote unit, this works as a momentary contact. AUX2 on the local unit

 

controls relay 2, which works as a toggle on / off (latching) control.

ALMODE= ...Set Alarm operation mode

NOFRZ/OLNFRZ/ FRZALL/TRKLST (default, OLNFRZ)

NOFRZ

No freeze mode - No frozen images are sent. If several alarms ocour to trigger the machine to dial, one shot from each will be sent in quick succession without any operator control. Any alarms present whilst on line will be indicated on the receive unit display baseline.

OLNFRZ

Offline alarm freeze - Only freezes the first alarm image and then transmits this image to the receiver. Subsequent alarms incoming while the uniit is transmitting to a receiver are flagged on the baseline but are not frozen, nor do they need to be acknowledged.

FRZALL

Freeze all alarm images - All alarm images are frozen. All must be acknowledged by the receiving station before the alarm can be cleared.

TRKLST

Track last alarm - No frozen images are sent. If several alarms ocour to trigger the machine to dial, one shot from each alarm will be sent in quick succession without any operator control, following an intruder. Any alarms present whilst on line will be displayed full screen and un frozen.