Guardian Technologies DVST, DFT 150/175 8.4ASCOM 5000 / CITAM, Atmode, Step Instruction, Remarks

Models: DVST DFT 150/175

1 80
Download 80 pages 50.9 Kb
Page 46
Image 46
8.4ASCOM 5000 / CITAM

Terminal Adapters

DVST Installation Guide

8.4ASCOM 5000 / CITAM

ATMODE

Cables required - 2x 15 to 15 (Part No. AS-DVST-X21). Dip switch settings can be used and should be set as follows:

Note: Switch 3 selects the sub address, if used.

Fig 5: ASCOM internal dip switch settings (ATMODE)

Step Instruction

1Using the pull handle, remove the circuit board module from the Citam 5000

2Adjust the dip switches as shown in Figure 9

3Press the select key four times so that the legend ‘CONF’ appears on the display.

4Press the enter key once and it will say ‘PRT1’, press the select key twice it will say ‘TA’ , press the enter key it will say ‘SHOW’.

5Press and hold select until the display reads ‘CHNG’, remove your finger from the select key and press the enter key, ‘ I N D B ’ will be displayed.

6Press the enter key, the message will be ‘ON’, use the select key to turn this to ‘OFF’, then press the enter key.

7Hold the select key and press the enter key, the display will return to ‘CONF’.

8At ‘CONF’ press the enter key, the display will read ‘PRT1’ for port 1.

Remarks

The Citam will now perform a self test. On completion the display will read ISDN.

This has turned of the in-band test feature of the unit.

Page 34

Dedicated Micros Ltd

Page 46
Image 46
Guardian Technologies DVST, DFT 150/175 manual 8.4ASCOM 5000 / CITAM, Atmode, Step Instruction, Remarks