Guardian Technologies DVST 5.7Define Auxiliary Ports 1,2, Port=, Set PORT usage, default settings

Models: DVST DFT 150/175

1 80
Download 80 pages 50.9 Kb
Page 24
Image 24
5.7Define Auxiliary Ports 1,2, 3

Setup

DVST Installation Guide

5.7Define Auxiliary Ports 1,2, 3

The auxiliary ports 1, 2, 3 on the DVST can be configured to operate with additional equipment i.e. printers, telemetry equipment and PC based conrol systems (MCI).

PORT=

Set PORT usage,

 

 

(Each field entry is separated by a space. If the

 

commands are entered correctly the new settings will

 

be displayed):

 

 

 

<AUX PORT> <BAUD RATE> <PARITY>

 

<DATA BITS> <STOP BITS> <FORMAT>

 

(default settings )

 

 

AUX1 N 8

1

38400

PKT

 

AUX2 N 8

1

38400

DATA

 

AUX3 N 8

1

9600

ENG

AUX PORTAUX1, AUX2, AUX3

BAUD RATE1200, 2400, 4800, 9600, 19200, 38400

PARITYN (None) O (Odd) E (Even)

DATA BITS5, 6, 7, or 8

STOP BITS1 or 2

FORMAT

Aux1DATACharacter based data operation

PKTPacket based operation

BLKBlock data operation

NULLTurn off port

Aux2DATACharacter based data operation

NULLTurn off port

Aux3TERMTerminal operation

PRINTSerial printer connection

MCIMachine control interface

DTMFSend telemetry codes to port

ENGDisplay debug messages

NULLTurn off port

Example

PORT = Aux3<space>9600<space>N<space>8<space>1<space>Term <return>

Page 12

Dedicated Micros Ltd

Page 24
Image 24
Guardian Technologies DVST 5.7Define Auxiliary Ports 1,2, Port=, Set PORT usage, Aux Port Baud Rate Parity, AUX1 N, 38400