5.5Define Camera Inputs

DVST Installation Guide

Setup

5.5Define Camera Inputs

MAX=nn Sets maximum number of cameras (default, 8)

Range is 1 to 16.

Correct settings of this ensures that any receiving station does not spend time trying to collect invalid camera inputs.

COL=nn

MON=nn

Set camera to Colour

Set camera to Monochrome (default, all cameras set to colour)

Format is COL=01, COL=05 etc. Format is MON=06, MON=15 etc.

It is important that camera inputs are correctly defined as colour or monochrome.

CAMnn=

Set camera title nn to ...

 

(default, Camera 01=CAMERA 01 etc.)

 

Format is CAM01=FRONT DOOR

5.6Auxiliary Port 3

The auxiliary port 3 on the DVST can be used for programming the DVST with a PC or for generating printer reports. Protocol is RS232 8 characters, no parity, one stop bit, default at 9,600 baud.

AUX=

Set AUX port usage:

 

TERM, PRINT, MCI, DTMF, ENG, NULL

 

(default, ENG)

TERM is for terminal operation, control by PC.

PRINT operates as a printer connection.

MCI is for machine control interface.

DTMF is used to echo telemetry codes at the port. ENG is used to display debug.

NULL turns the port off.

Note: Altering this command from a PC is valid, but after changing the setting the PC it will no longer communicate with the DVST. The reason is that the port has now been assigned a different task. .