Furuno DS-80 manual Demonstration Mode, System menu

Page 19

1.7.7 System menu 2

The System Menu 2 contains the diagnostic test and selection of dimmer control and display language.

1.Press the [MENU] key to open the menu.

2.Select SYSTEM MENU 2 and press the [ENT] key.

SYSTEM MENU2

TEST

DIMMER INTERNAL

/LANG. ENGLISH

ENT: SET

TEST: Checks the equipment for proper operation. For further details see Chapter 3.

DIMMER: See paragraph 1.3.2.

LANG.: Selects the language to use in menus, English or Japanese.

1.8Demonstration Mode

The demonstration mode outputs the Doppler speed signal to external equipment. This checks if the signal is being correctly output. )

1.Press the [MENU] key to open the menu.

2.Select DEMO and press the [ENT] key.

DEMO

SPEED

+10 . 0 kt

DATA DISPLAY

OFF

 

ENT: SET

3. Select SPEED and press the [ENT] key.

4.Select the digit to change with or .

5.Use or to set. (The setting range is

-10.0 to +40.0 kt, and the default setting is +10.0 kt.)

6.Press the [ENT] key.

7.Press the [ENT] key to open the DATA DISPLAY menu.

DEMO

 

SPEED

 

+10 . 0 kt

DATA DISPLAY

OFF

 

ON

 

OFF

 

ENT: SET

8.Press to select ON and press the [ENT] key.

9.Press the [MENU] key twice to close the menu.

The indication “DEMO” appears at the top right-hand corner when the demo mode is on. To turn off the demonstration display, show the DEMO menu and set SPD to OFF.

SPEED

DEMO

 

Demonstration

 

 

10.0 kt

mode "ON"

 

 

 

DISTANCE

11

Image 19
Contents Doppler Speed LOG 00080889601 Safety Instructions Record of Modifications in this OPERATOR’S Manual Table of Contents This page is intentionally left blank Specifications of the Doppler Speed LOG Safety Precaution Foreword FeaturesForeword Distribution BOX System ConfigurationPrinciple of Operation Beware of Transducer Location Remarks on UsageRemarks on Usage Conditions Affecting the AccuracyOperation of Display Unit Turning the Power On/OffPower on Power offPanel dimmer Adjusting Contrast, Panel DimmerSelecting a Display ContrastTo enter numerical data Main Menu OperationDistance Run Operation Selecting display methodPress the Omnipad at to select on Adjusting distance runResetting distance run to zero Select Data Display and press the ENT keySpeed offset calibration System SettingDisplaying the system menu Ship speed averageSpeed data selection Transducer offsetSelect Track Depth and press the ENT key System menu Demonstration ModeSelecting a display Digital Indicator DS-830, Distance Indicator DS-840Adjusting dimmer and contrast Operation of Optional EquipmentCorrection Factor for Analog Display MF-22A-1 Transducer maintenance MAINTENANCE, TroubleshootingMaintenance Preventive maintenanceGPS speed indication TroubleshootingProblem Probable cause Remedy General Doppler speed indicationPress the ENT key. The following display appears Diagnostics, Checking Program NumberControl Indication Transmission interval I/O SentencesInput sentences of IEC61162RX port Output sentences of IEC61162TX1, IEC61162TX2 portsOutput drive capability Max mA Schematic diagramsIEC61162 RX port IEC61162 TX1 portIEC61162 TX2 port GGA Global positioning system GPS fix data Sentence DescriptionTime, position and fix related data for a GPS receiver Actual course and speed relative to the ground VTG Course over ground and ground speedVLW Distance travelled through the water VBW Dual ground/water speedWater-referenced and ground-referenced speed data Longitudinal speed astern. * Not usedDistribution box DS-801 Parts Location and Parts ListParts Location Display unit DS-800Transceiver unit DS-810 Parts List Ref.Dwg C3441-K01-C 2000-01 Block.No Model DS-80 UnitNoise Filter Ref.Dwg C7247-K02-A 2000-01 Block.NoRef.Dwg C7247-K03-A 2000-01 Block No Calibration Sheet Menu Overview Default settings in bold italicDistance run Index