4. POWER SUPPLY

 

(1)

System Source

100/110/115/200/220/230 VAC:1.5/0.7 A max., 1 phase, 50-60 Hz

5. ENVIRONMENTAL CONDITION (IEC 60945)

(1)

Ambient Temperature

-15°C to +55°C (units for protected area)

 

 

Analog display: 0°C to +50°C

(2)

Relative Humidity

95% at 40°C

(3)

Vibration

IEC 60945 adopted

(4)Category of Equipment

Display Unit/Distance indicator/Transceiver Unit:

For protected area

Transducer:For submerged use, 600 kPa x 12 h

Distributor/Terminal box: For protected area

6. COATING COLOR

 

(1)

Display Unit

Cover: Munsell 2.5GY5/1.5 (light gray), Panel: N3.0 (gray)

(2)

Distribution Box

Munsell 2.5GY5/1.5 (light gray)

(3)

Transceiver Unit

Munsell 2.5GY5/1.5 (light gray)

(4)

Terminal Box

Munsell 2.5GY5/1.5 (light gray)

(5)

Analog Display

Munsell 2.5GY5/1.5 (light gray)

7. COMPASS SAFE DISTANCE

(1) Display Unit/Digital Indicator/Digital Distance Indicator

 

Standard: 0.50 m, Steering: 0.40 m

(2) Transceiver Unit

Standard: 2.05 m, Steering: 1.40 m

(3) Distribution Box

Standard: 3.10 m, Steering: 2.10 m

(4) Terminal Box

Standard: 0.65 m, Steering: 0.45 m

SAFETY PRECAUTION

-There is no unit giving rise to a dose rate > 0.5 mrem/h at 50 mm.

-There is no harmful radiation from the screen.

-All units of this equipment comply with EMC requirements in IEC 60945, as required by IMO Res. A.813 (19).

SP - 2

Image 8
Contents Doppler Speed LOG 00080889601 Safety Instructions Record of Modifications in this OPERATOR’S Manual Table of Contents This page is intentionally left blank Specifications of the Doppler Speed LOG Safety Precaution Foreword FeaturesForeword System Configuration Distribution BOXPrinciple of Operation Remarks on Usage Remarks on UsageConditions Affecting the Accuracy Beware of Transducer LocationTurning the Power On/Off Power onPower off Operation of Display UnitAdjusting Contrast, Panel Dimmer Selecting a DisplayContrast Panel dimmerMain Menu Operation Distance Run OperationSelecting display method To enter numerical dataAdjusting distance run Resetting distance run to zeroSelect Data Display and press the ENT key Press the Omnipad at to select onSystem Setting Displaying the system menuShip speed average Speed offset calibrationSelect Track Depth and press the ENT key Transducer offsetSpeed data selection Demonstration Mode System menuDigital Indicator DS-830, Distance Indicator DS-840 Adjusting dimmer and contrastOperation of Optional Equipment Selecting a displayCorrection Factor for Analog Display MF-22A-1 MAINTENANCE, Troubleshooting MaintenancePreventive maintenance Transducer maintenanceTroubleshooting Problem Probable cause Remedy GeneralDoppler speed indication GPS speed indicationControl Indication Diagnostics, Checking Program NumberPress the ENT key. The following display appears I/O Sentences Input sentences of IEC61162RX portOutput sentences of IEC61162TX1, IEC61162TX2 ports Transmission intervalSchematic diagrams IEC61162 RX portIEC61162 TX1 port Output drive capability Max mAIEC61162 TX2 port Time, position and fix related data for a GPS receiver Sentence DescriptionGGA Global positioning system GPS fix data VTG Course over ground and ground speed Actual course and speed relative to the groundVBW Dual ground/water speed Water-referenced and ground-referenced speed dataLongitudinal speed astern. * Not used VLW Distance travelled through the waterParts Location and Parts List Parts LocationDisplay unit DS-800 Distribution box DS-801Transceiver unit DS-810 Parts List Model DS-80 Unit Ref.Dwg C3441-K01-C 2000-01 Block.NoRef.Dwg C7247-K02-A 2000-01 Block.No Noise FilterRef.Dwg C7247-K03-A 2000-01 Block No Calibration Sheet Default settings in bold italic Menu OverviewIndex Distance run