Furuno DS-80 manual Specifications of the Doppler Speed LOG

Page 7

SPECIFICATIONS OF THE DOPPLER SPEED LOG

DS-80

1. GENERAL

 

(1)

Speed Range

Fore-Aft: -10.0 to +40 knots through-the-water

(2)

Distance Run

0.00 to 999,999.99 nautical miles through-the-water

(3)

Working Depth

Water depth greater than 3 m beneath the keel.

(4)

Working Frequency

1.0 MHz

(5)

Speed Accuracy

1.0% or 0.1 knots whichever is the greater

(6)

Distance Accuracy

1.0% or 0.1 nm whichever is the greater

Note:Accuracy is subject to shallow water effects, to the effect of wind, current and tide, and sensor location. Any ultrasonic equipment having the same frequency may interfere with speed measurement. The Doppler Log transducer should be installed apart from the

 

transducers of such kind of equipment.

2. DISPLAY UNIT

 

(1)

Display

Character size 15 or 21 mm H on monochrome LCD

(2)

Indication

 

 

Ship’s speed

Fore: c**.* knots (+40.0 kt max.)

 

 

Aft: d**.* knots (-10.0 kt max.)

 

Distance run

******.** nm

(3)

Other Function

Diagnostic check

3. DIGITAL INTERFACE

 

(1)

Serial Signal

 

 

Output:

2 ports; VBW, VLW in IEC 61162-1 (NMEA 0183 Ver 2.0)

 

Input:

1 port; IEC 61162 (NMEA 0183 Ver 2.0)

(2)

Analog Signal

Speed signal for Analog display: 2 port

 

 

-3.3 mA to 10 mA/ -10 kt to +30 kt

 

 

Analog current output: 1 port

 

 

4 mA to 20 mA/ -10 kt to 30 kt

 

 

Analog voltage output: 1 port

 

 

-3.3 V to 10 V/ -10 kt to 30 kt

(3)

Distance run output

2 ports; Contact closure each 0.005 nm, forward speed,

 

 

30 VDC: 0.4 A

(4)

System Check signal

1 port, 30 VDC: 0.2 A, default: closed

SP - 1

Image 7
Contents Doppler Speed LOG 00080889601 Safety Instructions Record of Modifications in this OPERATOR’S Manual Table of Contents This page is intentionally left blank Specifications of the Doppler Speed LOG Safety Precaution Foreword FeaturesForeword Distribution BOX System ConfigurationPrinciple of Operation Beware of Transducer Location Remarks on UsageRemarks on Usage Conditions Affecting the AccuracyOperation of Display Unit Turning the Power On/OffPower on Power offPanel dimmer Adjusting Contrast, Panel DimmerSelecting a Display ContrastTo enter numerical data Main Menu OperationDistance Run Operation Selecting display methodPress the Omnipad at to select on Adjusting distance runResetting distance run to zero Select Data Display and press the ENT keySpeed offset calibration System SettingDisplaying the system menu Ship speed averageSpeed data selection Transducer offsetSelect Track Depth and press the ENT key System menu Demonstration ModeSelecting a display Digital Indicator DS-830, Distance Indicator DS-840Adjusting dimmer and contrast Operation of Optional EquipmentCorrection Factor for Analog Display MF-22A-1 Transducer maintenance MAINTENANCE, TroubleshootingMaintenance Preventive maintenanceGPS speed indication TroubleshootingProblem Probable cause Remedy General Doppler speed indicationPress the ENT key. The following display appears Diagnostics, Checking Program NumberControl Indication Transmission interval I/O SentencesInput sentences of IEC61162RX port Output sentences of IEC61162TX1, IEC61162TX2 portsOutput drive capability Max mA Schematic diagramsIEC61162 RX port IEC61162 TX1 portIEC61162 TX2 port GGA Global positioning system GPS fix data Sentence DescriptionTime, position and fix related data for a GPS receiver Actual course and speed relative to the ground VTG Course over ground and ground speedVLW Distance travelled through the water VBW Dual ground/water speedWater-referenced and ground-referenced speed data Longitudinal speed astern. * Not usedDistribution box DS-801 Parts Location and Parts ListParts Location Display unit DS-800Transceiver unit DS-810 Parts List Ref.Dwg C3441-K01-C 2000-01 Block.No Model DS-80 UnitNoise Filter Ref.Dwg C7247-K02-A 2000-01 Block.NoRef.Dwg C7247-K03-A 2000-01 Block No Calibration Sheet Menu Overview Default settings in bold italicDistance run Index