3.3.2Nav User Frequencies

Up to 15 Nav User Frequencies can be saved with an assigned waypoint (WPT) identifier and Type.

3.3.2.1Viewing the Nav User Frequency

1.Press FUNC to access the Functions. Turn the LARGE knob to

select the Nav Frequency List Function. Turn the SMALL knob to view the Nav User Frequency function. Then, press ENT.

Press ENT Key To Set

Selected Freq As Standby

Active Frequency

 

 

 

 

 

 

 

Position In List.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Turn SMALL Knob

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

To Select Entry.

 

 

 

 

 

 

 

 

Press FLIP/FLOP

 

Key To Set

Selected

 

Frequency

 

 

Selected Freq As Active

 

 

 

 

 

 

 

Figure 3-16

Viewing User Nav Frequencies

2. Turn the SMALL knob to view the Nav User Frequencies.

3.Press and release the FLIP/FLOP key to set the displayed frequency as the Active frequency.

4.Press the ENT key to set the displayed frequency as the Standby frequency.

3.3.2.2Deleting the Nav User Frequency

1.While viewing a Nav User frequency, press the CLR key to delete the displayed User frequency.

Press ENT Key To Confirm

Deleting The Frequency

Active Frequency

 

 

 

 

 

 

 

Position In List.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Turn SMALL Knob

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

To Select Entry.

 

 

 

 

 

 

 

 

Press ENT To

 

Delete The

Selected

 

Frequency

 

 

Selected Freq

 

 

 

 

 

Figure 3-17 Deleting User Nav Frequencies

2. Press the ENT key to delete the displayed frequency.

190-01182-01 Rev. A

Garmin GNC 255A/255B Pilot’s Guide

3-11

Image 37
Contents GNC 255A/255B November Limited Warranty 190-01182-01 Rev. a Iii Operation US Toll Free Canada Toll Free Product Registration and SupportRecord of Revisions Contents 2.2 2.12.3 Index Index-1 This page intentionally left blank Product Description Getting StartedNav Volume/ID Knob Power/Com Volume/Squelch KnobPilot Controls FLIP/FLOP Key Tuning LARGE/SMALL Concentric Cursor Knobs5 C/N Com/Nav Key OBS KeyFunc Function Key USB PortMON Monitor Key Com Radio Power OnSelecting a Com Frequency Saving a Com Channel Monitoring the Standby Com ChannelAfter selecting the desired characters, press ENT After making a selection, press ENT DescriptionFrequency Database Reverse Look-Up Com Database Look-UpStuck Mic Emergency ChannelRemote Frequency Selection Control Selecting a Nav Frequency Nav RadioSaving a Nav Channel 01-36 Listening to the Nav Audio Channel14 CDI Display OBS Mode15 DST Data Display Distance/Speed/Time DST DisplayThis page intentionally left blank Functions Description FunctionsRecent Com Frequencies Com FrequenciesTurn the Small knob to select an Entry Press the CLR key to delete this User frequency Com User FrequenciesFrequencies. Press ENT Editing a Com User FrequencyCom Database Frequencies Com Database FrequenciesNearest APT function. Then, press ENT Com Nearest Airports APTTurn Small Knob To Scroll Through Available Frequencies Com Nearest Area Control Center ACC Frequencies13 Com Nearest FSS Frequencies Com Nearest Flight Service Station FSS Frequencies14 Com Nearest Weather Frequencies Com Nearest Weather WX FrequenciesRecent Nav Frequencies Nav FrequenciesPress the ENT key to delete the displayed frequency Nav User FrequenciesEditing a Nav User Frequency 21 Nav Database Frequencies Nav Database FrequenciesNav Nearest VOR When duplicate identifiers are found, press ENTAdjust Intercom ICS ConfigurationTurn the Small knob to display the available VORs Functions displayTurn the Small knob to turn the Aux Audio On or Off Aux AudioSpeaker On/Off Intercom On/OffIntercom On/Off function. Then, press the ENT key Speaker On/Off function. Then, press ENTCom Spacing System Configuration34 Set Display Brightness Display BrightnessDatabase Info Display ContrastDisplay Contrast function. Then, press the ENT key Database Version function. Then, press the ENT keyLoad Database function. Then, press the ENT key Load DatabaseSerial Number Software VersionSoftware Version function. Then, press the ENT key Press the Func key to return to the main menuSetting Up the Count Down Timer TimersTo select a starting timer value Viewing Timers in the Com Display Setting Up the Count Up TimerPressing CLR and then ENT will reset the displayed Timer Pressing ENT twice will stop the displayed Timer48 Count Down Timer Value Now Counting Up This page intentionally left blank Appendix TroubleshootingOr disabled via a Remote mounted It can be enabledIf in Lock Out mode Calibration error Recalibrate resolverUpdating the Frequency Database Messages Switch has been Power has been Re-apply power to the unitVerify glideslope deviation Property withInstallations All installationsRemote com Been in pressedNot communicating Nav radio is Contact dealer for serviceProperty with System This page intentionally left blank Index Remote frequency control 2-5 Reverse look-up 2-4 Revisions