RS-232
Connection
5 4 3 2 1
9 8 7 6
No.
1
2
3
4
5
6
7
8
9
Pin | Function |
Not used | |
Tx | Transmit |
Rx | Receive |
Not used | |
Gnd | Ground |
Not used | |
Not used | |
Not used | |
Not used |
Baud Rate: 9600bps | Data Bit: 8bits | Parity: None | Stop Bit: 1bit |
Command
The command codes are very sensitive, do not change capitalization, spacing, or lettering.
|
|
|
|
|
| System Command | Feedback | Function |
|
|
|
|
|
|
| Type | (Model #) | Brings up the model information |
|
| Lock | Lock | Locks the front panel of the Matrix switcher |
|
| Unlock | Unlock | Unlocks the front panel of the Matrix switcher |
|
| Version | (Firmware #) | Brings up the firmware version |
|
|
|
|
|
|
Each command or feedback is terminated with a carriage return.
Note: If the command fails or is incorrect the feedback should be “Command FAILED”
|
|
|
|
|
|
|
|
| Command | Feedback | Description |
|
|
|
| PWON | PWON | Turns power on |
|
|
|
| PWOFF | PWOFF | Turns power off |
|
|
|
| Statusx1 | x1AVx2 | Shows what input is connected to selected output |
|
|
|
| Status | x1AVx1, x2AVx2, | Displays which inputs are currently connected to which |
|
|
|
|
| x3AVx4, .... | outputs |
|
|
|
| Save[Y] | Save2 | Saves settings for future use, saves vary from 0 to 9 |
|
|
|
| Recall[Y] | Recall2 | Pulls up saved settings for the number you selected |
|
|
|
| Clear[Y] | Clear2 | Erases the save for the number you selected |
|
|
|
| EDIDMx1AVx2 | EDIDMx1AVx2 | Copies the EDID from output (x1) to Input (x2) |
|
|
|
|
|
| (output 3 to input 7 = EDIDMx3AVx2) |
|
|
|
| EDIDMInit | EDIDMInit | Resets EDID to factory settings |
|
|
|
|
|
|
|
|
|
|
| Undo | Undo | Cancels the previous command |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Toll free: | 9 | atlona.com |
Local: |