Icom IC-F5063, IC-F5062, IC-F5061 manual Transmit Adjustment, Power

Page 18

6-3 TRANSMIT ADJUSTMENT

Select an adjustment item using [] / [] keys, then set to the specified value using [] / [] keys on the connected PC’s keyboard.

ADJUSTMENT

ADJUSTMENT CONDITION

UNIT

OPERATION

 

 

 

VALUE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTPUT

1

• Channel

: CH 5

Rear

Connect an RF power meter to

 

50 W [USA]

POWER

 

• Transmitting

 

panel

the antenna connector.

25 W [EUR], [EXP]

[Power (Hi)]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[Power (L2)]

2

• Channel

: CH 6

 

 

 

25 W [USA]

 

 

 

• Transmitting

 

 

 

10 W [EUR], [EXP]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[Power (L1)]

3

• Channel

: CH 3

 

 

 

5.0 W [USA]

 

 

 

• Transmitting

 

 

 

2.5 W [EUR], [EXP]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MODULATION

1

Set the preset value of [MOD N] to “100” on the adjustment software.

 

 

 

 

 

 

 

 

BALANCE

 

 

 

 

 

 

 

 

 

 

 

 

 

2

• Channel

: CH 7

Rear

Connect the modulation ana-

Set to square wave

[BAL (Narrow)]

 

• No audio signals applied to the JIG cable.

panel

lyzer with an oscilloscope to the

 

 

 

form

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Set a modulation analyzer as;

 

antenna connector through an

 

 

 

 

 

 

 

 

 

 

 

HPF

: OFF

 

attenuator.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LPF

: 20 kHz

 

 

 

 

 

 

 

 

 

 

 

 

 

De-emphasis

: OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

Detector

: (P–P)/2

 

 

 

 

 

 

 

 

 

 

 

 

 

• Push [P0] while transmitting.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FM

1

• Connect an audio generator to the JIG

Rear

Connect the modulation ana-

±2.05 to ±2.15 kHz

DEVIATION

 

cable and set as;

 

panel

lyzer to the antenna connector

 

 

 

 

 

 

 

 

 

 

 

Frequency

: 1.0 kHz

 

through an attenuator.

 

 

 

 

 

 

 

 

 

 

 

Level

: 40 mV rms

 

 

 

 

 

 

 

 

 

 

Set the modulation analyzer to the same condition as “MODULATION BALANCE.”

Transmitting

(NARROW)

 

• Channel

: CH 8

 

 

 

[MOD N C]

 

• Transmitting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[MOD N L]

2

• Channel

: CH 9

 

 

 

 

 

 

 

 

• Transmitting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[MOD N H]

3

• Channel

: CH 10

 

 

 

 

 

 

 

 

• Transmitting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(WIDE)

4

• Channel

: CH 4

 

 

±4.05 to ±4.15 kHz

[MOD W C]

 

• Transmitting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[MOD W L]

5

• Channel

: CH 3

 

 

 

 

 

 

 

 

• Transmitting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[MOD W H]

6

• Channel

: CH 2

 

 

 

 

 

 

 

 

• Transmitting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(MIDDLE)*

7

• Channel

: CH 11

 

 

±3.15 to ±3.25 kHz

[MOD W C]

 

• Transmitting

 

 

 

 

 

 

 

 

 

 

 

 

[MOD M L]

8

• Channel

: CH 12

 

 

 

 

 

 

 

 

• Transmitting

 

 

 

 

 

 

 

 

 

 

 

 

[MOD M H]

9

• Channel

: CH 13

 

 

 

 

 

 

 

 

• Transmitting

 

 

 

 

 

 

 

 

 

 

 

 

DIGITAL

1

Set the preset value of [Digital Mode] to “7” on the adjustment software.

 

DAVIATION

 

 

 

 

 

 

2

• Attach the UT-119 to J2.

Rear

Connect the modulation ana-

±1.41 to ±1.45 kHz

[MOD D C]

 

(Refer to page 4-2 for the installation)

panel

lyzer to the antenna connector

 

 

 

 

 

 

 

 

 

 

 

 

• Channel

: CH 14

 

through an attenuator.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Transmitting

 

 

 

 

 

 

 

 

 

 

 

 

[MOD D L]

3

• Channel

: CH 15

 

 

 

 

 

 

 

 

• Transmitting

 

 

 

 

 

 

 

 

 

 

 

 

[MOD D H]

4

• Channel

: CH 16

 

 

 

 

 

 

 

 

• Transmitting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CTCSS/DTCS

1

• Channel

: CH 17

Rear

Connect a modulation analyzer to

±0.68 to ±0.72 kHz

DEVIATION

 

• No audio signals applied to the JIG cable.

panel

the antenna connector through

 

[CTCS/DTCS]

 

• Set the modulation analyzer to the same

 

an attenuator.

 

 

 

 

 

 

condition as “MODULATION BALANCE.”

 

 

 

 

 

 

 

 

• Transmitting

 

 

 

 

 

 

 

 

 

 

 

2TONE,

1

• Channel

: CH 18

Rear

Connect a modulation analyzer to

±1.50 kHz

5TONE,

 

• Transmitting

 

panel

the antenna connector through

 

DTMF

 

 

 

 

an attenuator.

 

[S.Tone]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*; [EUR] only.

 

 

 

 

 

 

6 - 5

Image 18
Contents VHF Transceivers Ordering Parts Model Version Channel Spacing TX PowerIntroduction Repair NotesContents Section Specifications USA EXP EURSection Inside Views Front UnitMain Unit Disassembly Instruction Removing the front panelOptional Units Installation Before Installing Optional UnitsOptional UT-96R or UT-119H installation Circuit Description Receiver CircuitsRF Circuits Transmitter Circuits Frequency Synthesizer Circuits APC CircuitPLL Circuits Power Supply Circuits Main Unit Power Supply CircuitsPLL IC Port Allocations CPU Main Unit IC14Converter Main Unit IC6 Before Starting Software Adjustment Adjustment ProceduresStarting Software Adjustment PreparationConnection JIG CableJIG Cable Adjustment Software Window Frequency Adjustment Adjustment Adjustment Condition Unit Operation ValueTransmit Adjustment PowerReceive Adjustment Adjustment Adjustment Condition Unit Location ValueConvenient Section Parts List Front UnitMain Unit IC9ARY EXB28V102JX POS PRF18BB471QB1RB CER ECJ0EB1H182K Connect Unit Accessories Mechanical PartsChassis Parts Unit abbreviations Section Board Layouts 6619B6618B Section Block Diagram Voltage Diagram PoswSUB To Main UnitGPS Electric Parts Main Unit Voltage DiagramSection Mechanical Parts Chassis Parts52,2  HTTPWWWICOMCOJPWORLDINDEXHTML