Icom IC-F5061 manual Frequency Adjustment, Adjustment Adjustment Condition Unit Operation Value

Page 17

6-2 FREQUENCY ADJUSTMENT

Select an adjustment item using [] / [] keys, then set to the specified value using [] / [] keys on the connected PC’s keyboard.

ADJUSTMENT

ADJUSTMENT CONDITION

UNIT

OPERATION

VALUE

 

 

 

 

 

 

 

PLL LOCK

1

Set the preset value of [LV (RX1)], [LV (RX2)] and [LV (TX)] to “204 [4.00V]” on the adjustment software.

VOLTAGE

 

 

 

 

 

 

(adjustment)

2

• Channel

: CH 1

PC

Click [Reload (F5)] button, then

4.00 V

[RX LVA1]

 

• Receiving

 

screen

check the “LVIN” item on the

 

 

 

 

 

 

CS-F5060 ADJ’s screen as below.

 

[RX LVA2]

3

• Channel

: CH 2

 

 

 

 

 

 

 

• Receiving

 

 

 

 

 

 

 

 

 

 

 

[TX LVA]

4

• Channel

: CH 2

 

 

 

 

 

• Transmitting

 

 

 

 

 

 

 

 

 

 

 

CONVENIENT: The “PLL LOCK VOLTAGE” can be adjusted automatically.

 

 

1: Set the Lock voltage preset ([LV RX1], [LV RX2], [LV TX]) to “204 (4.00 V).”

 

 

2: Put the cursor on [RX LVA1], [RX LVA2] and [TX LVA], then push the [ENTER] key on the connected PC’s keyboard.

 

 

 

 

 

 

 

PLL LOCK

1

• Channel

: CH 3

PC

Click [Reload (F5)] button, then

0.8–1.6 V

VOLTAGE

 

• Receiving

 

screen

check the “LVIN” item on the

(Verify)

(verify)

 

 

 

 

CS-F5060 ADJ’s screen.

 

2

• Channel

: CH 4

 

 

 

 

 

 

 

 

• Receiving

 

 

 

 

 

 

 

 

 

 

 

 

3

• Channel

: CH 3

 

 

 

 

 

• Transmitting

 

 

 

 

 

 

 

 

 

 

 

REFERENCE

1

• Channel

: CH 2

Top

Loosely couple a frequency

174.000000 MHz

FREQUENCY

 

• Connect an RF power meter to the

panel

counter to the antenna connector.

 

[REF]

 

antenna connector.

 

 

 

 

 

 

• Transmitting

 

 

 

 

PLL LOCK VOLTAGE will be appeared here

NOTE: The above screen is an example only.

Each item’s voltage will appear when pushing [Update] button.

6 - 4

Image 17
Contents VHF Transceivers Introduction Model Version Channel Spacing TX PowerOrdering Parts Repair NotesContents USA EXP EUR Section SpecificationsMain Unit Section Inside ViewsFront Unit Removing the front panel Disassembly InstructionBefore Installing Optional Units Optional Units InstallationOptional UT-96R or UT-119H installation RF Circuits Circuit DescriptionReceiver Circuits Transmitter Circuits PLL Circuits Frequency Synthesizer CircuitsAPC Circuit PLL IC Power Supply Circuits Main UnitPower Supply Circuits Converter Main Unit IC6 Port AllocationsCPU Main Unit IC14 Starting Software Adjustment Adjustment ProceduresBefore Starting Software Adjustment PreparationJIG Cable ConnectionJIG Cable Adjustment Software Window Adjustment Adjustment Condition Unit Operation Value Frequency AdjustmentPower Transmit AdjustmentConvenient Receive AdjustmentAdjustment Adjustment Condition Unit Location Value Front Unit Section Parts ListIC9 Main UnitARY EXB28V102JX POS PRF18BB471QB1RB CER ECJ0EB1H182K Connect Unit Chassis Parts AccessoriesMechanical Parts Unit abbreviations 6619B Section Board Layouts6618B Section Block Diagram Posw Voltage DiagramTo Main Unit SUBGPS Section Voltage DiagramElectric Parts Main Unit Mechanical Parts Chassis Parts52,2  HTTPWWWICOMCOJPWORLDINDEXHTML