5.3 OPERATING BATTERY CHARGE SYSTEM
1.Plug the end of CWC230 wall charger to the DC IN connector of the CCA250 charge adaptor.
2.Plug the wall charger into a 120 VAC wall outlet.
3.Turn the transceiver off.
4.Insert the transceiver. The indicator lights, and charging begins.
5.Remove the battery pack from charge adaptor when charging time has passed.
NOTE
The CWC230 can be replaced by the CAW240 mobile cable, or CWC232 120/230 VAC wall charger.
CAUTION
Never plug the power supply to the CCA250 charge adaptor except with a CAW240, CWC230 or CWC232.
5.4 CBT350 BATTERY TRAY
CBT350 is a battery tray that holds six AA alkaline batteries and is used with the HX350S transceiver.
1.Push both sides of the top case and remove the bottom case.
2.Install the battery cells into the top case, paying close attention to the
battery polarity markings on the case.
nWhen the HX350S is operated with the alkaline batteries, the battery life is as follows: (5/5/90 duty cycle)
•high power - 5 hours
•low power - 12 hours
Note that battery life is more than doubled if transceiver is consistently operated on low power.
NOTE
To ensure proper alignment of screw, rotate it counterclockwise a couple of times prior to tightening.
The battery indicator on the transceiver is only applicable to the CNB350/CNB350AS rechargeable battery. Disregard this indication when using alkaline batteries.