Dell R210 manual Power, Thermal, Acoustic, Power Supplies, Power Supply Connectors on the Planar

Page 26
5 Power, Thermal, Acoustic

Dell

5 Power, Thermal, Acoustic

5.1 Power Supplies

The base system includes a single 250W power supply. This unit provides power to the planar and the two internal hard drive bays. Power will be “soft-switched” allowing power cycling using a switch on the front of the system enclosure or through software control (server management functions). The power system is compatible with industry standards, such as ACPI and Server 2000.

Standard VRD (Voltage Regulator Down) modules that conform to VRD11.1 specification are used. This reduces the board layout complexity while offering design modularity. As processor speeds increase, a newer VRD can be used to accommodate the power increase with no need to re-spin the board. The VRD is integrated onto the planar and is not field upgradeable.

5.2 Power Supply Connectors on the Planar

There are 2 separate power supply connectors on the planar. One connector is an ATX connector (2x12) and the other one is a 2x2 connector to provide an additional two pins for +12V. The connector Pin definition (2 x 12 power connector) is not ATX standard.

The 2x12 connector provides 3.3V, 5V, 12V, and 12V standby to the system. (3.3V standby to system is generated from 12V standby).

 

Table 8.

Power Supply 24 Pins and Signals

 

 

 

 

 

Pin

SIGNAL

 

Pin

SIGNAL

1

P3V3

 

13

P3V3

 

 

 

 

 

2

P3V3

 

14

P12V1

 

 

 

 

 

3

GND

 

15

GND

 

 

 

 

 

4

P5V

 

16

PS_ON_N

 

 

 

 

 

5

GND

 

17

GND

 

 

 

 

 

6

P5V

 

18

GND

 

 

 

 

 

7

GND

 

19

GND

 

 

 

 

 

8

PS_PWROK

 

20

P12V1

 

 

 

 

 

9

P12V_STBY

 

21

P5V

 

 

 

 

 

10

P12V1

 

22

P5V

 

 

 

 

 

11

P12V1

 

23

P5V

 

 

 

 

 

12

P3V3

 

24

GND

 

 

 

 

 

 

Table 9.

Power Supply 4 Pins and Signals

 

 

 

 

 

Pin

SIGNAL

 

Pin

SIGNAL

1

GND

 

3

P12V2

 

 

 

 

 

2

GND

 

4

P12V2

 

 

 

 

 

PowerEdge R210 Technical Guide

26

Image 26
Contents Dell PowerEdge R210 Technical GuideInitial Release PowerEdge R210 Technical GuideDell AprilTable of Contents Dell Tables Figures 1 Product Comparison Comparison of PowerEdge Server Features PowerEdge R210 Technical Guide DellPowerEdge R210 Technical Guide 2.2 Detailed Information 2 New Technologies2.1 Overview 2.2.1 System ManagementS100 Feature/SpecComparison Overview PERC S100 and S300 S3002.2.3 eSATA Table 3. eSATA Modes3 System Overview Table 4. Product Feature SummaryMicrosoft Non- Factory Installed OS Option Power SupplyMicrosoft Factory Installed OS Options Factory Installed Linux OS Options4.1 Chassis Description 4.2 Dimensions and Weight4 Mechanical Figure 2. Front Panel View 4.3 Front Panel View and FeaturesFigure 1. Server Dimensions 4.6 NIC Indicators 4.4 Back Panel View and Features4.5 Power Supply Indicators 4.5.1 Power Button LED4.7 Side View Figure 5. Side View4.8 Internal Chassis View Figure 6. Internal Chassis ViewFigure 8. R210 Mounted In Four-Post Square-Hole Rack 4.9 RailsFigure 7. R210 Static Rails 4.12 Security 4.10 Fans4.11 Control Panel LED 4.12.1 Top Cover Lock MechanismTPM Pin Signals 4.12.4 Power Switch Security4.12.5 Intrusion Alert Figure 10. Intrusion Switch4.12.6 Secure Mode 4.14 Battery4.13 USB Ports See the Hardware Owner’s Manual 4.16 User Accessible Jumpers, Sockets, and Connectors4.15 Field Replaceable Units FRU Figure 12. Battery on Motherboard5.2 Power Supply Connectors on the Planar 5 Power, Thermal, Acoustic5.1 Power Supplies 5.3.2 Relative Humidity 5.3 Environmental Specifications5.3.1 Temperature 5.3.3 Maximum Vibration5.6 Thermal 5.4 Power Supply Unit PSU Specifications5.5 ENERGY STAR Compliance See the ENERGY STAR Compliance results on Dell.com5.7 Acoustics DefinitionsPowerEdge R210 Technical Guide 6.1 Overview 6.3 Processor Configurations6 Processors 6.2 Supported Processors7.2 DIMMs Supported 7 Memory7.1 Overview 7.5 Sparing 7.3 Slots/Risers7.4 Speed 7.6 Mirroring8.2 Direct Media Interface 8 Chipset8.1 Overview 8.3 PCI Express Interface8.9 Compatibility Module 8.7 Low Pin Count LPC Interface8.8 Serial Peripheral Interface SPI 8.10 Advanced Programmable Interrupt Controller APIC8.15.1 TCO Timer 8.14 Enhanced Power Management8.15 System Management Features 8.15.2 Processor Present Indicator8.17 Intel Anti-Theft Technology 8.15.4 Function Disable8.16 System Management Bus SMBus 8.18 Intel Virtualization Technology for Directed I/O8.19 JTAG Boundary-Scan 9 BIOS 9.1 Overview9.2 ACPI 9.3 Power Management Modes9.3.1 Dell Active Power Controller Table 15. Summary of R210 Power Management Features 9.3.2 Power Saving BIOS Setting OS Control9.3.3 Maximum Performance CPU Power and Performance Management Table 16. Power Profiles that R210 BIOS will Expose in BIOS SetupActive Power Controller Memory Power and Performance Management10 I/O Slots 10.1 Overview10.2 PCI Devices PCI Express Root PortMatrox G200eW w/ 8MB memory Table 17. I/O Slot InformationPCIe Table 18. PCI Card DimensionsTable 19. Bandwidth, Quantities, and Priorities 10.3 Boot Order 10.4 NICs11.2 Drives 11 Storage11.1 Overview Table 21. RAID Configurations 11.3 RAID Configurations11.4 Optical Disk Drive ODD 11.5 Tape Drives Table 22. Supported Tape Drives12.2 Audio 12 Video and Audio12.1 Video 13.2 Rails 13 Rack Information13.1 Overview 13.3 Cable Management Arm CMAInstall 14 Operating SystemsInstallation OperatingTable 25. Supported Linux Operating Systems InstallationInstall Operating15 Virtualization Table 26. Supported Virtualization OS16.2 Server Management 16 Systems Management16.1 Overview 16.4 Lifecycle Controller and Unified Server Configurator 16.3 Embedded Server ManagementTable 27. Unified Server Configurator Features and Description 16.5 iDRAC6 Express16.6 iDRAC6 Enterprise Features List for BMC, iDRAC6, and vFlash Page 17.2 USB Device 17 Peripherals17.1 USB 17.3 External Storage Table 30. External StorageTable 32. EMF Single Pack Dimensions and Weights 18 Packaging OptionsTable 31. AMF Single Pack Dimensions and Weights Figure 16. Packaging Appendix A. Regulatory Certifications Appendix B. R210 Volatility Tables Table 33. PowerEdge R210 VolatilityDell Table 34. Volatility Data Writing and Purpose Table 35. Methodology for Data Input to Memory Chipset Table 36. Methodology for Memory Protection and Clearing Control Panel DellChipset iDRAC6 Enterprise