Dell Power Profiles that R210 BIOS will Expose in BIOS Setup, Maximum Performance, OS Control

Page 42

Dell

USB wake

Generic

N/A

This feature is not supported on this system

 

 

 

since the S1 state is not supported.

 

 

 

 

DBS

N/A

Processor

This feature does P state transition under

 

 

MSRs

Windows

 

 

 

 

C State

N/A

Processor and

This feature allows multiple C state supports for

Support

 

PCH registers

Processor. This feature will work under

 

 

 

Windows and ACPI OS that understand C states.

 

 

 

 

Power Profile

N/A

Processor/IMC

11G Servers will be the most energy smart

support

 

and PCH

servers that Dell will ship. In addition to P,C

 

 

chipset

and T states, BIOS will expose the Power

 

 

registers.

Profiles to the OS. Each Power profile will have

 

 

 

a specific settings and it will fine tune

 

 

 

processor, MCH, IOH and South Bridge. For

 

 

 

detailed explanation on how this feature works,

 

 

 

please look at BIOS Power Management

 

 

 

specification located in Design Docs under R310

 

 

 

engineering.

 

 

 

 

Table 16. Power Profiles that R210 BIOS will Expose in BIOS Setup

Maximum Performance

DBPM Disabled ( BIOS will set P-State to MAX)

 

Memory frequency = Maximum Performance

 

Fan algorithm = Maximum Performance

 

 

OS Control

Enable OS DBPM Control (BIOS will expose

 

all possible P states to OS)

 

Memory frequency = Maximum Performance

 

Fan algorithm = Minimum Power

 

 

Active Power Controller

Enable DellSystem DBPM (BIOS will not make all P states

 

available to OS)

 

Memory frequency = Maximum Performance

 

Fan algorithm = Minimum Power

 

 

Custom

CPU Power and Performance Management:

 

Maximum Performance Minimum Power OS DBPM System

 

DBPM

 

Memory Power and Performance Management:

 

Maximum Performance 1333Mhz 1067Mhz 800Mhz

 

Minimum Power

 

Fan Algorithm

 

Maximum Performance Minimum Power

 

 

PowerEdge R210 Technical Guide

42

Image 42
Contents Dell PowerEdge R210 Technical GuideInitial Release PowerEdge R210 Technical GuideDell AprilTable of Contents Dell Tables Figures 1 Product Comparison Comparison of PowerEdge Server Features PowerEdge R210 Technical Guide DellPowerEdge R210 Technical Guide 2.2 Detailed Information 2 New Technologies2.1 Overview 2.2.1 System ManagementS100 Feature/SpecComparison Overview PERC S100 and S300 S3002.2.3 eSATA Table 3. eSATA Modes3 System Overview Table 4. Product Feature SummaryMicrosoft Non- Factory Installed OS Option Power SupplyMicrosoft Factory Installed OS Options Factory Installed Linux OS Options4.2 Dimensions and Weight 4 Mechanical4.1 Chassis Description 4.3 Front Panel View and Features Figure 1. Server DimensionsFigure 2. Front Panel View 4.6 NIC Indicators 4.4 Back Panel View and Features4.5 Power Supply Indicators 4.5.1 Power Button LED4.7 Side View Figure 5. Side View4.8 Internal Chassis View Figure 6. Internal Chassis View4.9 Rails Figure 7. R210 Static RailsFigure 8. R210 Mounted In Four-Post Square-Hole Rack 4.12 Security 4.10 Fans4.11 Control Panel LED 4.12.1 Top Cover Lock MechanismTPM Pin Signals 4.12.4 Power Switch Security4.12.5 Intrusion Alert Figure 10. Intrusion Switch4.14 Battery 4.13 USB Ports4.12.6 Secure Mode See the Hardware Owner’s Manual 4.16 User Accessible Jumpers, Sockets, and Connectors4.15 Field Replaceable Units FRU Figure 12. Battery on Motherboard5 Power, Thermal, Acoustic 5.1 Power Supplies5.2 Power Supply Connectors on the Planar 5.3.2 Relative Humidity 5.3 Environmental Specifications5.3.1 Temperature 5.3.3 Maximum Vibration5.6 Thermal 5.4 Power Supply Unit PSU Specifications5.5 ENERGY STAR Compliance See the ENERGY STAR Compliance results on Dell.com5.7 Acoustics DefinitionsPowerEdge R210 Technical Guide 6.1 Overview 6.3 Processor Configurations6 Processors 6.2 Supported Processors7 Memory 7.1 Overview7.2 DIMMs Supported 7.5 Sparing 7.3 Slots/Risers7.4 Speed 7.6 Mirroring8.2 Direct Media Interface 8 Chipset8.1 Overview 8.3 PCI Express Interface8.9 Compatibility Module 8.7 Low Pin Count LPC Interface8.8 Serial Peripheral Interface SPI 8.10 Advanced Programmable Interrupt Controller APIC8.15.1 TCO Timer 8.14 Enhanced Power Management8.15 System Management Features 8.15.2 Processor Present Indicator8.17 Intel Anti-Theft Technology 8.15.4 Function Disable8.16 System Management Bus SMBus 8.18 Intel Virtualization Technology for Directed I/O8.19 JTAG Boundary-Scan 9 BIOS 9.1 Overview9.3 Power Management Modes 9.3.1 Dell Active Power Controller9.2 ACPI 9.3.2 Power Saving BIOS Setting OS Control 9.3.3 Maximum PerformanceTable 15. Summary of R210 Power Management Features CPU Power and Performance Management Table 16. Power Profiles that R210 BIOS will Expose in BIOS SetupActive Power Controller Memory Power and Performance Management10 I/O Slots 10.1 Overview10.2 PCI Devices PCI Express Root PortMatrox G200eW w/ 8MB memory Table 17. I/O Slot InformationTable 18. PCI Card Dimensions Table 19. Bandwidth, Quantities, and PrioritiesPCIe 10.3 Boot Order 10.4 NICs11 Storage 11.1 Overview11.2 Drives 11.3 RAID Configurations 11.4 Optical Disk Drive ODDTable 21. RAID Configurations 11.5 Tape Drives Table 22. Supported Tape Drives12 Video and Audio 12.1 Video12.2 Audio 13.2 Rails 13 Rack Information13.1 Overview 13.3 Cable Management Arm CMAInstall 14 Operating SystemsInstallation OperatingTable 25. Supported Linux Operating Systems InstallationInstall Operating15 Virtualization Table 26. Supported Virtualization OS16 Systems Management 16.1 Overview16.2 Server Management 16.4 Lifecycle Controller and Unified Server Configurator 16.3 Embedded Server Management16.5 iDRAC6 Express 16.6 iDRAC6 EnterpriseTable 27. Unified Server Configurator Features and Description Features List for BMC, iDRAC6, and vFlash Page 17 Peripherals 17.1 USB17.2 USB Device 17.3 External Storage Table 30. External Storage18 Packaging Options Table 31. AMF Single Pack Dimensions and WeightsTable 32. EMF Single Pack Dimensions and Weights Figure 16. Packaging Appendix A. Regulatory Certifications Appendix B. R210 Volatility Tables Table 33. PowerEdge R210 VolatilityDell Table 34. Volatility Data Writing and Purpose Table 35. Methodology for Data Input to Memory Chipset Table 36. Methodology for Memory Protection and Clearing Control Panel DellChipset iDRAC6 Enterprise