Intel SC450NX manual Attach the Small Bar of the Slide Assembly to the Server

Page 15

Attach the Small Bar of the Slide Assembly to the Server

See Figure 4.

1.Remove four screws from the kit.

2.While facing the side of the server, orient the small bar so that the flat side faces the top and the right-angle end faces the front of the server.

3.Align the first hole in the right-angle end of the bar with the first threaded hole in the side of the chassis.

4.Insert a screw through the hole in the bar and into the chassis wall. Then loosely tighten the screw.

5.Align the rest of the holes in the bar with the remaining three threaded holes along the side of the chassis.

6.Insert three more screws through the bar and into the threaded holes in the chassis wall. Then tighten all four screws firmly (6.0 inch-pounds).

7.Install the remaining small bar on the other side of the chassis by repeating steps 1–6 above.

Figure 4. Small Bar of the Slide Assembly

1Threaded hole in chassis

2Safety latch

3Screw

4Small outer bar (right-angle end)

15

Image 15
Contents SC450NX MP Server Rack/Pedestal Kit Installation Guide Page Copyright ã 1998, Intel Corporation. All Rights Reserved Page Server Precautions Safety GuidelinesPage Equipment Rack Precautions Viii Contents Page Introduction Tools You Need SC450NX MP Server Physical SpecificationsPrepare the Slide Assemblies Configuring for Rack MountAttaching the Bezel Frame and Door Prepare the ServerAttach the Small Bar of the Slide Assembly to the Server Right-angle Bracket and Vertical Rail Prepare the Equipment RackCenter Bar and Large Outer Bar Assembly Install the Server in the Rack Installing the Server in the Rack Page Configuring for Pedestal Mount Install Chassis FeetInstall the Top and Side Covers Install Bezel Frame and Door Remove the Covers Changing from Pedestal to RackExchange the Bezel Frame