Intel SC450NX manual Center Bar and Large Outer Bar Assembly

Page 17

Attach the Center Bar and Large Outer Bar Assemblies to the Equipment Rack

See Figure 6.

1.Orient a center bar and large outer bar assembly so that the flat side is facing toward the brackets attached to the vertical rails and the safety latch on the center bar is near the back of the rack.

2.Press the flat side of the outer bar into the U-shaped sections of the brackets.

3.Slide the assembly toward the front of the rack until the end of the outer bar is flush with the end of the U-shaped section of the front bracket.

4.Gently slide the center bar toward the front of the rack, and position the oblong slot in it over the first hole in the large outer bar. Insert a screw through the hole in the bar and the first hole in the front bracket. Place a lock washer and a nut on the screw, and loosely tighten it.

5.Position the oblong slot in the center bar over the third hole back from the front of the large outer bar. Insert an 8-32 screw through the hole and the oblong slot in the front bracket. Place a lock washer and an 8-32 nut on the screw, and loosely tighten it.

6.The back bracket has two holes and three slots in it. This end of the outer bar has four holes in it. Which holes and slots you use depend on the depth of the equipment rack. After fitting the bar into the bracket, insert two screws through the holes in the bar and the appropriate oblong slots in the bracket. Place a lock washer and a nut on each screw, and loosely tighten them.

7.Ensure that the brackets and bars are positioned correctly in the rack. Then tighten all screws firmly (6.0 inch-pounds).

1 Back right-angle extension bracket

2 Screw

3 Flat washer, lock washer, and nut

4 Large outer bar

5 Safety latch on the center bar

6 Center bar

7 Front right-angle extension bracket

Figure 6. Center Bar and Large Outer Bar Assembly

17

Image 17
Contents SC450NX MP Server Rack/Pedestal Kit Installation Guide Page Copyright ã 1998, Intel Corporation. All Rights Reserved Page Server Precautions Safety GuidelinesPage Equipment Rack Precautions Viii Contents Page Introduction Tools You Need SC450NX MP Server Physical SpecificationsPrepare the Slide Assemblies Configuring for Rack Mount Attaching the Bezel Frame and Door Prepare the ServerAttach the Small Bar of the Slide Assembly to the Server Right-angle Bracket and Vertical Rail Prepare the Equipment RackCenter Bar and Large Outer Bar Assembly Install the Server in the Rack Installing the Server in the Rack Page Install the Top and Side Covers Configuring for Pedestal MountInstall Chassis Feet Install Bezel Frame and Door Remove the Covers Changing from Pedestal to RackExchange the Bezel Frame