HOW DO YOU TEST YOUR PFD USING THE MANUAL INFLATOR?

The U.S.Coast Guard recommends that you purchase at least one spare re-arming kit (MA7214).

1)To test your Inflatable PFD, you will need your fully armed Inflatable PFD, and re-arming kit approved for your Inflatable PFD: MA7214.

2)Put on the Inflatable PFD.

3)Actuate the inflation system by jerking firmly downward on the pull-tab. The Inflatable PFD should fully inflate within 5 seconds.

4)Get into shallow water, just deep enough that you can stand with your head above the surface.

5)See if the Inflatable PFD will float you on your back or just slightly back of vertical. In a relaxed floating position, verify that your mouth is well above the water’s surface. Note the effect of where you hold your legs and how you float.

6)Get out of the water and remove the Inflatable PFD. Completely deflate the Inflatable PFD using the oral inflator (see Deflating the Inflatable PFD p. 7).

7)Let the Inflatable PFD dry thoroughly. Re-arm (p. 9) and Repack the PFD (p. 13).

HOW DO YOU TEST YOUR PFD USING THE ORAL INFLATOR?

This test is not mandatory, however may be conducted using the following procedure.

WARNING: Use only a previously fired hydrostatic inflator to perform this test . DO NOT test with a fully armed hydrostatic inflator as double inflation may occur, possibly resulting in cell damage.

1)No spare parts or re-arming kits are needed to test your Inflatable PFD.

2)Put on the Inflatable PFD.

Inflatable PFD Owner’s Manual

21

Image 23
Contents MD3183 Inflatable PFD Contents Approval Conditions and Carriage Requirements WHY are Pfds Required Safety EQUIPMENT? What is AN Inflatable PFD?MD3183 Unpacked Instructions for USEComponent Inspection Instructions Readiness ChecklistUninspected Commercial Vessel Use About the readiness of your Inflatable PFD Sizing and Fit Donning InstructionsInflating Your Inflatable PFD Information Automatic Backup InflationManual Inflation Automatic InflatorSpecial Considerations for Inflatable Devices Deflating the Inflatable PFDYour device is ready to be repacked see Repacking p Usage Below FreezingImportant Ensure all air has been removed from the PFD Re-arming Your PFD Dispose of the used inflator body TrashShaft Ring BlackRepacking Fold over the top side E and cover F Fasten the Velcro tab H to keep zipper closed Sailing Harness Check the following at the intervals listed below Is Your PFD in Good and Serviceable CONDITION? Every Two 2 Months Ii Ensure the manual pull-tab is accessible Before Each Use Vi Ensure the single point status indicator is green Fig Cleaning and Storing of Your Inflatable PFDHOW and WHY to Test Your PFD HOW do YOU Test Your PFD Using the Automatic INFLATOR? Put on the Inflatable PFD HOW do YOU Test Your PFD Using the Oral INFLATOR?Hypothermia Wear Your PFDHow hypothermia affects most adults Page Do not Attach PFD’S to Your Boat Inflatable PFD Safety AccessoriesAdditional Information WE Save Lives for a Living