Mustang Survival MD3183, MD3184 manual Deflating the Inflatable PFD

Page 9

NOTE: Oral inflation may cause the Inflatable PFD to break-out suddenly (loudly) if any of the zippers are closed.

ii.Locate the oral inflation tube by opening the wearer’s left front panel of the Inflatable PFD. Remove the dust cap from the end of the oral tube and blow into the tube until the Inflatable PFD is fully inflated.

FIGURE 5

Special Considerations for Inflatable Devices

The Inflatable PFD might not be armed when needed, either knowingly or unknowingly. Inadvertant inflation causes several risks that you must address to avoid drowning. Much less common but also important are:

1)Double inflation (CO2 cylinder inflation after full oral inflation) could damage the Inflatable PFD,

2)Inflation when stored in a tight space could damage the Inflatable PFD, and

3)The Inflatable PFD could inflate when you are in an awkward place or position.

If this Inflatable PFD should inflate inadvertantly, a re-arm kit (MA7214) is required to re-arm the device.

IMPORTANT: The Inflatable PFD should be re-armed according to the instructions (Re-arming Your PFD, p. 9).

Deflating the Inflatable PFD

1)To deflate the Inflatable PFD, reverse the oral-inflation tube dust cap and insert it into the valve or depress valve with fingertip. The dust

Inflatable PFD Owner’s Manual

7

Image 9
Contents MD3183 Inflatable PFD Contents Approval Conditions and Carriage Requirements WHY are Pfds Required Safety EQUIPMENT? What is AN Inflatable PFD?MD3183 Unpacked Instructions for USE Readiness Checklist Uninspected Commercial Vessel Use Component Inspection Instructions Donning Instructions Inflating Your Inflatable PFDAbout the readiness of your Inflatable PFD Sizing and Fit Manual Inflation Automatic Backup InflationAutomatic Inflator InformationSpecial Considerations for Inflatable Devices Deflating the Inflatable PFDUsage Below Freezing Important Ensure all air has been removed from the PFDYour device is ready to be repacked see Repacking p Re-arming Your PFD Dispose of the used inflator body TrashShaft Ring BlackRepacking Fold over the top side E and cover F Fasten the Velcro tab H to keep zipper closed Sailing Harness Check the following at the intervals listed below Is Your PFD in Good and Serviceable CONDITION?Ii Ensure the manual pull-tab is accessible Before Each UseEvery Two 2 Months Cleaning and Storing of Your Inflatable PFD HOW and WHY to Test Your PFDVi Ensure the single point status indicator is green Fig HOW do YOU Test Your PFD Using the Automatic INFLATOR? Put on the Inflatable PFD HOW do YOU Test Your PFD Using the Oral INFLATOR?Hypothermia Wear Your PFDHow hypothermia affects most adults Page Inflatable PFD Safety Accessories Additional InformationDo not Attach PFD’S to Your Boat WE Save Lives for a Living