SUPER MICRO Computer AS1021M-T2, AS1021M-82 user manual Rack Mounting Considerations

Page 19

Chapter 2: Server Installation

Rack Mounting Considerations

Ambient Operating Temperature

If installed in a closed or multi-unit rack assembly, the ambient operating tempera- ture of the rack environment may be greater than the ambient temperature of the room. Therefore, consideration should be given to installing the equipment in an environment compatible with the manufacturer’s maximum rated ambient tempera- ture (Tmra).

Reduced Airflow

Equipment should be mounted into a rack so that the amount of airfl ow required for safe operation is not compromised.

Mechanical Loading

Equipment should be mounted into a rack so that a hazardous condition does not arise due to uneven mechanical loading.

Circuit Overloading

Consideration should be given to the connection of the equipment to the power supply circuitry and the effect that any possible overloading of circuits might have on overcurrent protection and power supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.

Reliable Ground

A reliable ground must be maintained at all times. To ensure this, the rack itself should be grounded. Particular attention should be given to power supply connec- tions other than the direct connections to the branch circuit (i.e. the use of power strips, etc.).

2-3

Image 19
Contents AS1021M-T2 AS1021M-82 Manual Revision Release Date October 3 About This Manual PrefaceManual Organization Bios System SafetyAdvanced Serverboard Setup Advanced Chassis SetupPreface Table of Contents Advanced Serverboard Setup System SafetySgpio Advanced Chassis SetupAppendices BiosPage Overview Chapter IntroductionSerial ATA Serverboard FeaturesProcessors MemoryServer Chassis Features Cooling System SATA/SCSI SubsystemControl Panel BackplaneNVidia MCP55 Pro Chipset System Block Diagram Asia-Pacific Contacting SupermicroHeadquarters EuropePreparing for Setup Chapter Server InstallationUnpacking the System Rack Precautions Choosing a Setup LocationServer Precautions Rack Mounting Considerations Installing the Inner Rails Installing the System into a RackIdentifying the Sections of the Rack Rails Locking Tabs Installing the Outer RailsInstalling the Server into a Rack Installing the Server into the RackInstalling the Server into a Telco Rack Installing the Server into a Telco RackChecking the Serverboard Setup Accessing the Inside of the System Checking the Drive Bay Setup Control Panel Buttons Chapter System InterfaceControl Panel LEDs Drive Carrier LEDs Page Electrical Safety Precautions Chapter System SafetyGeneral Safety Precautions ESD Precautions Installing the Onboard Battery Operating PrecautionsUnpacking Chapter Advanced Serverboard SetupPrecautions Handling the ServerboardInstalling the CPU Backplates Processor and Heatsink InstallationInstalling the Processor install to the CPU#1 socket first Page Installing the Heatsink Installing the Heatsink Retention ModulesConnecting Data Cables Connecting CablesConnecting Power Cables Front Control Panel Header Pins JF1 Connecting the Control PanelI/O Ports Installing MemoryOptimizing memory performance Memory Support3b. Top View of DDR Slot Adding PCI Cards PCI card installationPCI Expansion Slots H8DMR-82 Layout Serverboard DetailsConnectors Description Jumpers Description Default SettingH8DMR-82/H8DMR-i2 Quick Reference NMI Button ATX Power ConnectorProcessor Power Connector Auxiliary Power ConnectorOverheat/Fan Fail LED Power LEDUniversal Serial Bus Ports USB0/1 Power Fail LEDReset Button Power ButtonJLAN1/2 Ethernet Ports Extra USB HeadersSerial Ports Fan HeadersOverheat LED Power LED/SpeakerATX PS/2 Keyboard and PS/2 Mouse Ports Chassis IntrusionWake-On-Ring Wake-On-LANCompact Flash Card PWR Connector 3rd Power Supply Alarm Reset HeaderPower Fail Header Jumper SettingsExplanation Jumpers VGA Enable/Disable 3rd Power Supply Fail Detect Enable/DisableCmos Clear Watch Dog I2C to PCI Enable/DisablePCI-X Slot Freq. Select Scsi Termination Enable/ Disable H8DMR-82 only Scsi Controller Enable/ Disable H8DMR-82 onlyCompact Flash Master Slave Scsi Activity LEDs H8DMR- 82 only Onboard Indicators+5V Standby Power LED LAN1/LAN2 LEDsFloppy, IDE, Sata and Scsi Drive Connections Floppy ConnectorSata Ports IDE ConnectorDiffsens Termpwr Scsi Connectors H8DMR-82 onlyPage Static-Sensitive Devices Chapter Advanced Chassis SetupTools Required Chassis Front and Rear Views Control PanelReplacing System Cooling Fans Installing a new fanSystem Fans System Fan FailureRemoving the Front Bezel Drive Bay Installation/RemovalRemoving the Front Bezel Accessing the Drive BaysMounting a SATA/SCSI drive in a drive carrier SATA/SCSI Drive InstallationInstalling/removing hot-swap SATA/SCSI drives DVD-ROM and Floppy Drive Installation Removing the power supply Power SupplyPower Supply Failure Removing/Replacing the Power SupplyRemoving/Replacing the Power Supply Chapter Starting the Setup UtilityIntroduction Bios Features Advanced Settings MenuMain Menu Advanced Acpi Configuration Floppy/IDE/SATA Configuration NVidia RAID SetupBlock Multi-Sector Transfer LBA/Large ModePrimary IDE Master/Slave TypeSerial ATA0/1/2 Primary/Secondary Channel DMA ModeA.R.T Bit Data TransferDMA Mode PCI/PnP Configuration NorthBridge Configuration Advanced Chipset ControlSouthBridge Configuration Device Configuration Processor Clock OptionsConsole Redirection DMI Event LoggingSystem Fan Monitor Hardware Health ConfigurationFAN1 Speed Down Time Level1 TemperatureLevel2 Temperature FAN1 Speed through FAN5 SpeedIpmi 1.5 Configuration Removable Drives Boot MenuBoot Device Priority Hard Disk DrivesSecurity Menu OS InstallationCD/DVD Drives Exit Menu Amibios Error Beep Codes Appendix a Bios Error Beep CodesBeep Code Error Message Description Page Uncompressed Initialization Codes Appendix B Bios Post Checkpoint CodesBootblock Recovery Codes Uncompressed Initialization Codes Checkpoint Appendix B Bios Post Checkpoint Codes Checkpoint A9h Aah Abh B0h B1h 00h Page Appendix C System Specifications Chassis WeightPower Supply MotherboardRegulatory Compliance